MAUDE Adverse Event Report: ABBOTT MEDICAL FAST-CATH¿ TRANSSEPTAL GUIDING INTRODUCER SL SERIES, SL0¿ 10F; INTRODUCER, CATHETER

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ABBOTT MEDICAL FAST-CATH¿ TRANSSEPTAL GUIDING INTRODUCER SL SERIES, SL0¿ 10F; INTRODUCER, CATHETER Back to Search Results
Model Number 406968
Medical Device Problem Codes Fluid/Blood Leak (1250); Gas/Air Leak (2946)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 05/28/2025
Type of Reportable Event Malfunction
Event or Problem Description
During the atrial fibrillation procedure, the sheath was inserted into the right atrium.When the viewflex catheter was inserted into the sheath, air was aspirated from the side port, and blood leaked from the hemostasis valve.The sheath was replaced, but again when the viewflex catheter was inserted, air was aspirated from the side port, and blood leaked from the hemostasis valve.The second sheath was replaced which resolved the issue and the procedure was completed with no adverse consequences to the patient.
 
Additional Manufacturer Narrative
Additional information: d9, g3, h2, h3, h6.One 10f fast-cath introducer sheath and dilator were received for evaluation.The sheath passed pressure and aspiration leak testing with no anomalies observed.The cap was removed from the hemostasis hub and the hemostasis seal was microscopically inspected.Tearing was noted on both sides of the seal.The device history record was reviewed to ensure that each manufacturing and inspection operation was performed.The cause of the damaged seal remains unknown.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
FAST-CATH¿ TRANSSEPTAL GUIDING INTRODUCER SL SERIES, SL0¿ 10F
Common Device Name
INTRODUCER, CATHETER
Manufacturer (Section D)
ABBOTT MEDICAL
5050 nathan lane north
plymouth MN 55442
Manufacturer (Section G)
ABBOTT MEDICAL
5050 nathan lane north
plymouth MN 55442
Manufacturer Contact
wendy mccarty
5050 nathan lane n
plymouth, MN 55442
6517565400
MDR Report Key22301920
Report Number3005334138-2025-00369
Device Sequence Number15594043
Product Code DYB
UDI-Device Identifier05414734203562
UDI-Public(01)05414734203562(10)10729210(17)280131
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
K061015
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 08/25/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number406968
Device Catalogue Number406968
Device Lot Number10729210
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 05/30/2025
Supplement Date Received by Manufacturer08/19/2025
Initial Report FDA Received Date06/20/2025
Supplement Report FDA Received Date08/25/2025
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured02/17/2025
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-