(b)(4).Date sent: 7/1/2025.B3: publication year of 2021.D4: batch # unk.D4: udi: as the lot number for the device involved in the event was not provided, the full udi is currently not available.D4: udi: the expiration date is currently not available.Therefore, the full udi is currently not available.This report is being submitted as part of a retrospective review of published scientific articles captured under capa-014204.This report is related to a journal article; therefore, no product will be returned for analysis and the manufacturing records cannot be reviewed as the lot/batch number has not been provided.This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon, or its employees that the report constitutes an admission that the product, ethicon, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.
|
|
Title: a comparative study of cold dissection tonsillectomy and harmonic scalpel tonsillectomy under microscope - our experience authors: sunil kumar samdani, jugal kishore, vipasha yogi, sanjay sharma, amreen.Citation cite: (december 2022) 74(suppl 3):s5395¿s5403; https://doi.Org/10.1007/s12070-021-02586-w.The aim of this prospective comparative study is to compare different variables such as tonsillectomy time, intraoperative blood loss, post operative pain and wound healing with the two methods (harmonic scalpel and cold dissection) under microscopic visualisation to select the best method according to the patient¿s condition.From july 2019 to june 2020, a total of 40 cases with ages between 4¿14 years (mean age of 8 years in which 31 were males and 9 were females) diagnosed as adeno-tonsillar hypertrophy of grade 3-4 were studied.Age and gender distribution has no effect in comparison of outcomes as each patient underwent tonsillectomy by cold dissection method on one side and by ultrasonic scalpel on other and this was decided by odd even method of randomization.Microscope was used for tonsillectomy on either side.In cold dissection method done by eve¿s tonsillar snare.On the side assigned to the harmonic scalpel, tonsillectomy was performed using the hook blade (harmonic scalpel, synergy, ethicon endosurgery, llc guaynabo, puerto rico 00,969 usa).Reported complications include intraoperative blood loss, post operative pain, delayed wound healing.In conclusion, harmonic tonsillectomy had better outcome with respect to operation time, intraoperative blood loss, post-operative pain and post operative haemorrhage when compared to cold dissection tonsillectomy.In view of wound healing, cold dissection tonsillectomy was found to be better than harmonic scalpel tonsillectomy.
|