BOSTON SCIENTIFIC CORPORATION AUTOTOME RX 39; UNIT, ELECTROSURGICAL, ENDOSCOPIC (WITH OR WITHOUT ACCESSORIES) Back to Search Results
Model Number M00545190
Medical Device Problem Codes Break (1069); Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 06/09/2025
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Block h6: imdrf device code a0401 captures the reportable event of cutting wire broken.Imdrf impact code f2301 captures the reportable event of additional device required (net).
 
Event or Problem Description
It was reported to boston scientific corporation that an autotome rx 39 was used in the duodenum and common bile duct during an endoscopic retrograde cholangiopancreatography (ercp) procedure to treat stones performed on (b)(6) 2025.During sphincterotomy, the tech bowed the tome slightly and the cut wire popped off the catheter.The detached cut wire was successfully retrieved using a net.The procedure was completed with another of the same device.There were no patient complications reported as a result of this event.
 
Additional Manufacturer Narrative
Block h6: imdrf device code a0401 captures the reportable event of cutting wire broken.Imdrf impact code f2301 captures the reportable event of additional device required (net).Block h11: investigation results the returned autotome rx 39 was analyzed, and a visual and microscopic inspection found that cutting wire was blackened, kinked and broken at 8 mm from the proximal pierce hole.No other problems with the device were noted.With all the available information, boston scientific concludes the reported event of cutting wire break was confirmed.The results of the analysis performed on the returned device found that the cutting wire was kinked and broken at 8 mm from the proximal pierce hole.Based on the condition of the device, the problem found could have been generated if there was contact between the device and the scope during energization or if the generator exceeded the maximum of voltage during the procedure.Also, energizing the device prior to performing sphincterotomy can compromise the cutting wire's integrity and cause a premature cutting wire fatigue.Once the cutting wire breaks, any attempt to remove the device from the scope can bent the cutting wire.It is most likely that procedural or anatomical factors encountered during the use of the device could have affected the device performance and its integrity.Based on all gathered information, the most probable root cause of this complaint is adverse event related to procedure.
 
Event or Problem Description
It was reported to boston scientific corporation that an autotome rx 39 was used in the duodenum and common bile duct during an endoscopic retrograde cholangiopancreatography (ercp) procedure to treat stones performed on (b)(6) 2025.During sphincterotomy, the tech bowed the tome slightly and the cut wire popped off the catheter.The detached cut wire was successfully retrieved using a net.The procedure was completed with another of the same device.There were no patient complications reported as a result of this event.
 
Additional Manufacturer Narrative
H6: imdrf device code a0401 captures the reportable event of cutting wire broken.Imdrf impact code f2301 captures the reportable event of additional device required (net).H11: investigation results: the returned autotome rx 39 was analyzed, and a visual inspection found that cutting wire was blackened, kinked and broken at 8 mm from the proximal pierce hole.No other problems with the device were noted.With all the available information, boston scientific concludes the reported event of cutting wire break was confirmed.The results of the analysis performed on the returned device found that the cutting wire was kinked and broken at 8 mm from the proximal pierce hole.Based on the condition of the device, the problem found could have been generated if there was contact between the device and the scope during energization or if the generator exceeded the maximum of voltage during the procedure.Also, energizing the device prior to performing sphincterotomy can compromise the cutting wire's integrity and cause a premature cutting wire fatigue.Once the cutting wire breaks, any attempt to remove the device from the scope can bent the cutting wire.It is most likely that procedural or anatomical factors encountered during the use of the device could have affected the device performance and its integrity.Based on all gathered information, the most probable root cause of this complaint is adverse event related to procedure.
 
Event or Problem Description
It was reported to boston scientific corporation that an autotome rx 39 was used in the duodenum and common bile duct during an endoscopic retrograde cholangiopancreatography (ercp) procedure to treat stones performed on (b)(6) 2025.During sphincterotomy, the tech bowed the tome slightly and the cut wire popped off the catheter.The detached cut wire was successfully retrieved using a net.The procedure was completed with another of the same device.There were no patient complications reported as a result of this event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
AUTOTOME RX 39
Common Device Name
UNIT, ELECTROSURGICAL, ENDOSCOPIC (WITH OR WITHOUT ACCESSORIES)
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
2546 calle primera
alajuela
CS  
Manufacturer Contact
arlene acevedo gutierrez
300 boston scientific way
marlborough, MA 01752
7877968283
MDR Report Key22399143
Report Number3005099803-2025-02990
Device Sequence Number14652580
Product Code KNS
UDI-Device Identifier08714729444763
UDI-Public(01)08714729444763(17)280226(10)35946990
Combination Product (Y/N)N
Initial Reporter StateIL
Initial Reporter CountryUS
PMA/510(K) Number
K013153
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup,Followup
Report Date (Section B) 09/08/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberM00545190
Device Catalogue NumberM00545190
Device Lot Number0035946990
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 06/10/2025
Supplement Date Received by Manufacturer07/18/2025
08/19/2025
Initial Report FDA Received Date07/03/2025
Supplement Report FDA Received Date08/11/2025
09/08/2025
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured02/26/2025
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient SexUnknown
-
-