| Catalog Number |
67125805D |
| Medical Device Problem Code |
Fluid/Blood Leak (1250)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
|
A healthcare professional reported that an envoy da, 6f, 105cm, mpd catheter hub (67125805d, lot unknown) is not working to remove air inside hub.There was no patient injury reported.
|
| |
|
Additional Manufacturer Narrative
|
|
Manufacturer ref#: (b)(4).Information regarding patient weight, height, medical history, race, and ethnicity was not reported.Section b3 ¿ date of event: the date of the event was not reported.Section d4: udi: as the lot number for the device involved in the event was not provided, the full udi is currently not available.Section h3: the device is available to be returned for evaluation and testing.However, it has not been received to date.If the device returns, a device investigation will be performed.Section h4: the device manufacture date is not known as the device lot number is not available / not reported.Missing information from this report is identified as blank; this information was not provided in the reported event or available at the time of report submission.The company is seeking this information through the event investigation.This report is being submitted pursuant to the provisions of 21 cfr, part 803 (and/or part 4, as applicable).This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by cerenovus, or its employees that the report constitutes an admission that the product, cerenovus, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.
|
| |
|
Additional Manufacturer Narrative
|
|
Manufacturer ref#: (b)(4).Updated sections on this medwatch: b4, d9, g3, g6, h2, h3 and h11.The product has been returned for evaluation and testing; however, the engineering evaluation has not been completed.A supplemental report will be submitted if new facts arise which materially alter information submitted in a previous mdr report.
|
| |
|
Additional Manufacturer Narrative
|
|
Manufacturer ref# (b)(4).Updated sections on this medwatch: b4, g3, g6, h2, h3, h6 and h11.Complaint conclusion: a healthcare professional reported that an envoy da, 6f, 105cm, mpd catheter hub (67125805d, lot unknown) is not working to remove air inside hub.There was no patient injury reported.No additional information was available.The device was returned to j&j medtech for further evaluation.A non-sterile envoy da, 6f, 105cm, mpd catheter was received contained in the decontamination pouch.Upon receiving the device, visual inspection was performed, and no apparent damage was noted.The proximal end of the catheter was inspected under magnification and no cracks nor fractures were found either on the luer hub nor the proximal end of the shaft.No exposed internal wires nor breaks in the device¿s integrity were found.The catheter was flushed using a lab sample syringe, and no water leakage that could indicate a crack was identified.Since no break in device integrity was found, the issue regarding a cracked condition on the proximal end of the catheter cannot be confirmed.There is no indication that the issue reported in the complaint is related to a manufacturing issue.The kink and compressed conditions were not originally reported, and the exact time of occurrence cannot be determined.It is suggested that these damages could be the result of the handling post-procedure of the device; therefore, these are not considered related to the issue reported.Multiple attempts to obtain additional information were unsuccessful.If information is provided at a later date, the file will be reopened and processed accordingly.As part of the j&j medtech quality process, all devices are manufactured, inspected, and released to approved specifications.Since there was no evidence to suggest the event was related to a manufacturing or design issue, no capa activity is required at this time.It should be noted that product failure is multifactorial.The instructions for use contain the following precaution: do not use a catheter that has been damaged in any way.If damage is detected, replace it with another envoy guiding catheter that is not damaged.As part of the post market surveillance program, information from this complaint is trended to identify statistical signals for consideration of further correction action.Since there was no evidence to suggest the event was related to a manufacturing or design issue, no corrective actions will be taken at this time.A supplemental report will be submitted if new facts arise which materially alter information submitted in a previous mdr report.
|
| |
|