| Catalog Number |
113643026 |
| Medical Device Problem Codes |
Loss of or Failure to Bond (1068); Device Dislodged or Dislocated (2923)
|
| Health Effect - Clinical Code |
Joint Dislocation (2374)
|
| Date of Event |
06/17/2025
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
It was reported that patient has a history of multiple dislocation with closed reduction.Last closed reduction knocked the glenoid component loose.There was glenoid loosening at the cement/implant interface and competitor cement was used.Surgeon removed the glenoid component and 52 18 std head and put in 52 18 ecc head with posterior eccentricity as tendency to pop out anteriorly.The stem was well fixed.Treated like ream and run did not the reimplant the glenoid.This occurred on the left side.There was no broken implants.The past dislocations were what was revised in this surgery.All parts of the head and glenoid were removed.Doi: unknown, dor: (b)(6) 2025, affected side: left shoulder.
|
| |
|
Additional Manufacturer Narrative
|
|
Product complaint # (b)(4).Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If the information is unknown, not available or does not apply, the section/field of the form is left blank.H11 additional narrative: d4: udi: as the lot number for the device involved in the event was not provided, the full udi is currently not available.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|
Additional Manufacturer Narrative
|
|
Product complaint # (b)(4).Investigation summary: no device associated with this report was received for examination.An evaluation of the manufacturing record could not be performed as the required product/lot number was not provided to complete the evaluation.As part of our company quality system process, all devices are manufactured, inspected, and distributed to approved specifications.Additional complaint information monitoring for potential safety signals will be conducted through complaint trending as part of the post-market surveillance.If additional information is made available, the investigation will be updated as applicable.Device history lot: the device lot number is unknown; therefore, a device history review could not be performed.If the lot/serial number becomes available, the record will be re-assessed.H11 additional narrative: added: d10 (concomitant).
|
| |
|
Search Alerts/Recalls
|