| Catalog Number |
0102L18 |
| Medical Device Problem Code |
Material Puncture/Hole (1504)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
07/02/2025
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
|
It was reported on (b)(6) 2025, patient mrn# (b)(6) was brought to or room #1 for a cystoscopy and insert ureteral catheters by the physician and a laparoscopic low anterior rectum resection by another physician.During the cystoscopy physician was unable to insert the ureteral catheters but was able to place an 18 french foley ref# (b)(4).At the start of the part of the procedure the foley did not stay in the patient and fell out of the patient.On request of the physician another foley was brought into the room and placed in the patient.That was a 16 french foley ref# (b)(4), as the procedure was going on that foley fell out as well.Two more 16 french foleys were placed ref# (b)(4) with the same results.And then attempted to place a 16 french 2way coude ref# (b)(4) and 18 french 2way coude ref# (b)(4) with the same results.Physician was asked to assist at this point and was able to successfully place a 20 french 2way coude ref# (b)(4).
|
| |
|
Additional Manufacturer Narrative
|
|
The investigation is still in progress.Once the investigation is complete a supplemental report will be filed.Udi format updated with available product information per gudid.H11: section a through f - the information provided by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
| |
|
Event or Problem Description
|
|
It was reported on (b)(6) 2025, patient mrn# (b)(6) was brought to operating room #1 for a cystoscopy and insert ureteral catheters by the physician and a laparoscopic low anterior rectum resection by another physician.During the cystoscopy physician was unable to insert the ureteral catheters but was able to place an 18 french foley ref# (b)(4).At the start of the part of the procedure the foley did not stay in the patient and fell out of the patient.On request of the physician another foley was brought into the room and placed in the patient.That was a 16 french foley ref# (b)(4), as the procedure was going on that foley fell out as well.Two more 16 french foleys were placed ref# (b)(4) with the same results.And then attempted to place a 16 french 2way coude ref# (b)(4) and 18 french 2way coude ref# (b)(4) with the same results.Physician was asked to assist at this point and was able to successfully place a 20 french 2way coude ref# (b)(4).
|
| |
|
Additional Manufacturer Narrative
|
|
The reported event was inconclusive because this investigation did not result in any additional findings and no sample was available for evaluation.No actions can be taken at this time since a root cause was not identified.A dhr review is not required as the lot number is unknown.The instructions for use were found adequate and states the following: sterile unless package is opened or damaged.Warning: on catheter, do not use ointments or lubricants having petrolatum base.They will damage latex and may cause the balloon to burst.Caution: do not aspirate urine through drainage funnel wall.Storage: store catheters at room temperature away from direct exposure to light, preferably in the original box.Single patient use only.Do not reuse.Do not resterilize.For urological use only.Valve type: use luer slip tip syringe.Do not use needle.Recommended inflation capacities 3cc balloon: use 5ml sterile water 5cc balloon: use 10ml sterile water 15cc balloon: use 20ml sterile water 20cc balloon: use 25ml sterile water 30cc balloon: use 35ml sterile water 40cc balloon: use 45ml sterile water 75cc balloon: use 80ml sterile water do not exceed recommended capacities.Warning: after use, this product may be a potential biohazard.To deflate catheter balloon: gently insert a luer slip tip syringe in the catheter valve.Never use more force than is required to make the syringe ¿stick¿ in the valve.Allow the pressure within the balloon to force the plunger back and fill the syringe with water.If you notice slow or no deflation, re-seat the syringe gently.Use only gentle aspiration to encourage deflation if needed.Vigorous aspiration may collapse the inflation lumen, preventing balloon deflation.If permitted by hospital protocol, the valve arm may be severed.If this fails, contact adequately trained professional for assistance, as directed by hospital protocol.Should balloon rupture occur, care should be taken to assure that all balloon fragments have been removed from the patient.Visually inspect the product for any imperfections or surface deterioration prior to use.Udi format updated with available product information per gudid.H11: section a through f - the information provided by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
| |
|