| Catalog Number |
151820032 |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Codes |
Pain (1994); Loss of Range of Motion (2032); Synovitis (2094); Swelling/ Edema (4577)
|
| Date of Event |
06/11/2025
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
It was reported that on (b)(6) 2020, the patient underwent a tka surgery for oa following a tibial fracture.The salesperson was informed that a synovectomy was performed on (b)(6) 2025, under arthroscopic observation using a patella crank.There was a lot of synovial proliferation, so it was directly removed in an open procedure.The removal surgery was performed due to limited range of motion and the patient's pain.The surgery was completed successfully with no surgical delay.The surgeon commented the followings.- the relatively distal movement of the joint surface and the observed swelling of the patellar tendon may have been a factor.- it is recognized that a certain number of ps suffer from patella crank syndrome, regardless of the model.In this case, crs femur was used, and the box retio was slightly higher than the ps.
|
| |
|
Additional Manufacturer Narrative
|
|
This report is being submitted pursuant to the provisions of 21 cfr, part 803 (and/or part 4, as applicable).This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by depuy synthes, or its employees that the report constitutes an admission that the product, depuy synthes, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.Additional narrative: d4: udi: as the lot number for the device involved in the event was not provided, the full udi is currently not available.
|
| |
|
Additional Manufacturer Narrative
|
|
Product complaint #(b)(4).Investigation summary: no device associated with this report was received for examination.An evaluation of the manufacturing record could not be performed as the required product/lot number was not provided to complete the evaluation.As part of our company quality system process, all devices are manufactured, inspected, and distributed to approved specifications.Additional complaint information monitoring for potential safety signals will be conducted through complaint trending as part of the post-market surveillance.If additional information is made available, the investigation will be updated as applicable.Device history lot: the device lot number is unknown, therefore a device history review could not be performed.If the lot/serial number becomes available, the record will be re-assessed.H11 additional narrative: added: d10.
|
| |
|
Search Alerts/Recalls
|