MAUDE Adverse Event Report: CORDIS US CORP SABER; CATHETER, ANGIOPLASTY, PERIPHERAL, TRANSLUMINAL

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

CORDIS US CORP SABER; CATHETER, ANGIOPLASTY, PERIPHERAL, TRANSLUMINAL Back to Search Results
Catalog Number 48005025X
Medical Device Problem Code Burst Container or Vessel (1074)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 06/23/2025
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
E1 phone number: (b)(6).Additional information is pending and will be submitted within 30 days upon receipt.
 
Event or Problem Description
As reported, the 5mm 25cm.018 saber percutaneous transluminal angioplasty (pta) balloon catheter ruptured.The procedure was completed using another.018 saber balloon.There was no reported injury to the patient.The device had been stored and prepared in accordance with the instructions for use (ifu).There was no difficulty removing the product from the hoop.There was no difficulty removing the protective balloon cover.There was no difficulty removing the stylet or any of the sterile packaging components.No kinks or other damages were noted prior to inserting the product into the patient.The device was prepped per the ifu.The device prepped normally, maintaining negative pressure.The intended procedure was for the superficial femoral artery (sfa).The lesion was severely calcified.The vessel tortuosity was severe.There was no resistance or friction while inserting the balloon through the rotating hemostatic valve.There was no resistance or friction while inserting the balloon through the guide catheter.There was no difficulty advancing the balloon catheter through the vessel.There was no difficulty crossing the lesion with the balloon catheter.The catheter was never in an acute bend.The balloon catheter did not kink while being used.The product will be returned for further analysis.
 
Additional Manufacturer Narrative
As reported, the 5mm 25cm.018 saber percutaneous transluminal angioplasty (pta) balloon catheter ruptured.The procedure was completed using another.018 saber balloon.There was no reported injury to the patient.The device had been stored and prepared in accordance with the instructions for use (ifu).There was no difficulty removing the product from the hoop.There was no difficulty removing the protective balloon cover.There was no difficulty removing the stylet or any of the sterile packaging components.No kinks or other damages were noted prior to inserting the product into the patient.The device was prepped per the ifu.The device prepped normally, maintaining negative pressure.The intended procedure was for the superficial femoral artery (sfa).The lesion was severely calcified.The vessel tortuosity was severe.There was no resistance or friction while inserting the balloon through the rotating hemostatic valve.There was no resistance or friction while inserting the balloon through the guide catheter.There was no difficulty advancing the balloon catheter through the vessel.There was no difficulty crossing the lesion with the balloon catheter.The catheter was never in an acute bend.The balloon catheter did not kink while being used.A non-sterile unit of ¿saber 5mm25cm 150¿ was received for analysis coiled inside of a clear plastic bag.The device was unpacked to proceed with the product evaluation.A thorough inspection was performed observing an axial burst on the balloon.No other outstanding details were observed.Functional test was performed.One inflator/deflator device was attached to the inflation port.Balloon inflation test was done applying positive pressure using the inflator/deflator device with the purpose of reaching the rated burst pressure (rbp).However, inflation pressure was not maintained due to the burst condition observed on the balloon.The balloon was inspected with a vision system observing a rupture on the surface where the water is leaking.The balloon surface presented evidence of a rupture condition with elongations and secondary scratch marks located near the damaged border area the reported event of ¿balloon burst¿ was not observed through analysis of the returned device since no leakage or rupture of the balloon was observed during the functional analysis.The cause of the reported issue could not be determined.Unspecified procedural, handling, and/or anatomical factors may have contributed to the reported issue.However, the damage observed is commonly caused during the interaction of the material with a sharp object or mechanical damage.It is very likely that the same factors that caused the observed scratch marks and elongations on the surface could probably lead to the damaged condition found on the received device.It seems that the material near the damaged area was affected by a sharp object from the outside of the device, such as the severe calcification reported.According to the warnings in the safety information in the instructions for use, ¿prior to angioplasty, the catheter should be examined to verify functionality and integrity, and ensure that its size and shape are suitable for the specific procedure for which it is to be used.Do not use if product damage is suspected or evident.To reduce the potential for vessel damage or the risk of dislodgement of particles it is very important that the inflated diameter of the balloon should approximate the diameter of the vessel just proximal and distal to the lesion.The balloon dimensions are printed on the product label.The compliance table incorporated with the product shows how balloon diameter increases as pressure increases.Do not exceed the rated burst pressure recommended on the label.The rated burst pressure is based on the results of in vitro testing.At least 99.9% of the balloons (with a 95% confidence) will not burst at or below their rated burst pressure.Use of a pressure monitoring device is recommended to prevent over-pressurization.Pressure in excess of the rated burst pressure can cause balloon rupture and potential inability to withdraw the catheter through the introducer sheath.Balloon rupture can cause vessel damage and the need for additional intervention.Use only the recommended balloon inflation medium (a 50/50 mixture by volume of contrast medium and normal saline).Never use air or any gaseous medium to inflate the balloon.¿ based on the information available for review, there is no indication to suggest that the reported failure could be related to the design or manufacturing process of the unit.Therefore, no corrective/preventative actions will be taken at this time.
 
Event or Problem Description
As reported, the 5mm 25cm.018 saber percutaneous transluminal angioplasty (pta) balloon catheter ruptured.The procedure was completed using another.018 saber balloon.There was no reported injury to the patient.The device had been stored and prepared in accordance with the instructions for use (ifu).There was no difficulty removing the product from the hoop.There was no difficulty removing the protective balloon cover.There was no difficulty removing the stylet or any of the sterile packaging components.No kinks or other damages were noted prior to inserting the product into the patient.The device was prepped per the ifu.The device prepped normally, maintaining negative pressure.The intended procedure was for the superficial femoral artery (sfa).The lesion was severely calcified.The vessel tortuosity was severe.There was no resistance or friction while inserting the balloon through the rotating hemostatic valve.There was no resistance or friction while inserting the balloon through the guide catheter.There was no difficulty advancing the balloon catheter through the vessel.There was no difficulty crossing the lesion with the balloon catheter.The catheter was never in an acute bend.The balloon catheter did not kink while being used.The product will be returned for further analysis.
 
Event or Problem Description
As reported, the 5mm 25cm.018 saber percutaneous transluminal angioplasty (pta) balloon catheter ruptured.The procedure was completed using another.018 saber balloon.There was no reported injury to the patient.The device had been stored and prepared in accordance with the instructions for use (ifu).There was no difficulty removing the product from the hoop.There was no difficulty removing the protective balloon cover.There was no difficulty removing the stylet or any of the sterile packaging components.No kinks or other damages were noted prior to inserting the product into the patient.The device was prepped per the ifu.The device prepped normally, maintaining negative pressure.The intended procedure was for the superficial femoral artery (sfa).The lesion was severely calcified.The vessel tortuosity was severe.There was no resistance or friction while inserting the balloon through the rotating hemostatic valve.There was no resistance or friction while inserting the balloon through the guide catheter.There was no difficulty advancing the balloon catheter through the vessel.There was no difficulty crossing the lesion with the balloon catheter.The catheter was never in an acute bend.The balloon catheter did not kink while being used.The product will be returned for further analysis.
 
Additional Manufacturer Narrative
This device is available for analysis, but the engineering report is not yet available.However, it will be submitted within 30 days upon receipt.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SABER
Common Device Name
CATHETER, ANGIOPLASTY, PERIPHERAL, TRANSLUMINAL
Manufacturer (Section D)
CORDIS US CORP
14201 nw 60 avenue
miami lakes FL 33014
Manufacturer (Section G)
CORDIS US CORP.
14201 nw 60 avenue
miami lakes FL 33014
Manufacturer Contact
karla castro
coyol free zone, building b25, ,  , costa rica
el coyol alajuela bld 25 
7863138372
MDR Report Key22438042
Report Number3007635982-2025-00153
Device Sequence Number11563454
Product Code LIT
UDI-Device Identifier20705032069561
UDI-Public(01)20705032069561(17)261231(10)82301542
Combination Product (Y/N)N
Initial Reporter CountryUS
PMA/510(K) Number
K971010
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup,Followup
Report Date (Section B) 08/19/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Catalogue Number48005025X
Device Lot Number82301542
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 06/24/2025
Supplement Date Received by Manufacturer07/10/2025
08/18/2025
Initial Report FDA Received Date07/08/2025
Supplement Report FDA Received Date08/04/2025
08/19/2025
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured01/10/2024
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
N/A.
Patient SexUnknown
-
-