Per information provided: (b)(6) 2012 ¿ patient was diagnosed with two incisional hernias thereby underwent laparoscopic repair with the implant of sepramesh ip (device #1, device #2).Per op notes, ¿a sepramesh ip (device #1) was placed to anterior abdominal wall and secured using tacker.Another piece of sepramesh ip (device #2) was placed to left lower quadrant hernia defect and tacked with sorbafix.¿ (b)(6) 2012 ¿ patient had abdominal pain and diagnosed with recurrent incisional hernia thereby underwent laparoscopic repair with the implant of ventralight st (device #3).Per op notes, ¿extensive midline and left lower quadrant adhesions noted to the undersurface of the prior mesh (device #1, #2) was taken down.Hernia defect was noted in the midline.A ventralight st (device #3) was placed into anterior abdominal wall and tacked using sorbafix.¿ (b)(6) 2012 ¿ patient was diagnosed with wound infection thereby underwent incision and drainage of wound infection and purulent drainage was noted in mid abdomen.(b)(6) 2012 ¿ patient was diagnosed with infected ventral hernia mesh thereby underwent open repair with the removal of meshes (device #1, #2, #3) and implant of xenmatrix (device #4).Per op notes, ¿the small bowel tightly adherent to the underlying mesh (device #1, #3) was lysed.The meshes (device #1, #3) were removed from the anterior abdominal wall.Between the two pieces of mesh, there was an abscess.In left lower quadrant, adhesions of the bowel to the mesh were taken down and mesh (device #2) was removed.There were a lot of adhesions and scarring of a portion of the omentum overlying certain bowel loop.A xenmatrix (device #4) was stitched to left lower quadrant using sutures and then a rest of piece of mesh was placed as underlay to fascia and overlay using sutures.¿ (b)(6) 2012 ¿ patient was diagnosed with abdominal wall wound dehiscence and wound infection.(b)(6) 2013 ¿ patient was diagnosed with infected abdominal wound thereby underwent open repair with the removal of xenmatrix (device #4).Per op notes, ¿a very dense adhesion was noted.The xenmatrix (device #4) noted to be folded over and the mesh at the superior aspect of the fascia was removed.¿.
|
|
Root cause is inconclusive; no conclusion can be made as to the extent to which the implant may have caused or contributed to the patient's postoperative course.Note, the manufacturing date (15-aug-2011) is considered to be a best estimate.This emdr represents the bard xenmatrix (device #4).An additional emdr was submitted to represent the bard sepramesh ip (device #2) and additional supplemental emdrs were submitted to represent bard sepramesh ip (device #1) and ventralight st (device #3).Note: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|