| Catalog Number |
8065921540 |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Codes |
Conjunctivitis (1784); Corneal Edema (1791); Inflammation (1932); Intraocular Pressure Increased (1937); Red Eye(s) (2038); Blurred Vision (2137); Eye Pain (4467); Toxic Anterior Segment Syndrome (TASS) (4469)
|
| Date of Event |
05/28/2025
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
A nurse reported that following a cataract with intraocular lens (iol) implant procedure, the patient had tass (toxic anterior segment syndrome) on post-operative day one, with inflammation confined to the anterior chamber.Unspecified topical steroids were started and follow up has been scheduled.Additional information has been requested, received and stated tass onset was seen on post-operative day one following surgery on the right eye.Cultures were not performed.Conjunctival inflammation, aqueous cells and aqueous fibrin were present.By post-operative day six, the patient had eye pain, trace corneal edema and scleral redness.Medication adjustments were made, noted potential for surgical intervention of lens rotation due to blurry vision from 031 degree to 180 degree.Inflammation and fibrin were reported to be improving.Intraocular pressure was noted as increased and treated topically with unspecified medication.Patient took nsaids (non-steroidal anti-inflammatory drugs), antibiotics and steroids as a post operative medication.Additional information was received that the patient had undergone intraocular lens repositioning surgery on post-operative day twenty-nine.The patient was evaluated one day post intraocular lens repositioning surgery and was noted with mild inflammation, which was expected to improve, and vision was blurry.Patient current condition was continuing.The patient will be further monitored due to additional surgery for significant findings.This report pertains to ophthalmic knife involved for this reported event.
|
| |
|
Additional Manufacturer Narrative
|
|
Investigation including root cause analysis is in progress.A supplemental mdr will be filed as necessary in accordance with 21 cfr 803.56 when additional reportable information becomes available.The manufacturer internal reference number is: (b)(4).H.10 reflects all related report numbers associated with this product event that have been submitted at this time.
|
| |
|
Event or Problem Description
|
|
Additional information indicated that the most recent chart note was from a nine-day postoperative visit following intraocular lens (iol) repositioning.The blurriness had improved, although the vision remained somewhat blurry.However, the general postoperative appearance was good, with no signs of toxic anterior segment syndrome (tass).The patient was advised to return for serial refractions at future visits.
|
| |
|
Additional Manufacturer Narrative
|
|
Additional information is provided in section b.5.The manufacturer internal reference number is: (b)(4).H.10 reflects all related report numbers associated with this product event that have been submitted at this time.
|
| |
|
Additional Manufacturer Narrative
|
|
A sample was not received at the manufacturing site for evaluation for the reported event; therefore, the condition of the product could not be verified.A review of the device history record traceable to the reported lot number, indicates that the reported product was processed and released according to the reported product¿s acceptance criteria.The investigation conducted a non-conformance review of the reported lot number.No deviations were identified and all corresponding production release specifications defined in the device master record were met.Based on the evaluation of the information received, the investigation was unable to identify the root cause or origin of the reported event.Additionally, no manufacturing-related deficiencies were found that potentially could have contributed to the complaint.As the root cause and its origin are inconclusive, further investigative or manufacturing actions are not warranted at this time.All knives are 100% inspected by trained operators using a minimum of 10x magnification during manufacturing.Receipt of additional relevant information or supporting materials will prompt a re-evaluation of the complaint investigation.Complaint data for all manufacturer products is reviewed monthly to monitor for adverse trends.During the last review, no adverse trends were observed for the reported product and event combination.Quality assurance has reviewed this complaint and will continue to monitor data for evidence of adverse trending and take further action, as appropriate.No further action warranted at this time.The manufacturer internal reference number is: (b)(4).H.10 reflects all related report numbers associated with this product event that have been submitted at this time.
|
| |
|