| Model Number |
LX3 |
| Medical Device Problem Codes |
Defective Component (2292); Unintended Movement (3026)
|
| Health Effect - Clinical Code |
Insufficient Information (4580)
|
| Date of Event |
06/11/2025
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Investigation including root cause analysis is in progress.A supplemental mdr will be filed as necessary in accordance with 21 cfr 803.56 when additional reportable information becomes available.The manufacturer internal reference number is: (b)(4).
|
| |
|
Event or Problem Description
|
|
A healthcare professional reported that the ophthalmic microscope's camera mount was damaged, and the microscope head handles were loose.Procedure details and patient impact have not been provided.Additional information has been requested; none has been received till date.
|
| |
|
Additional Manufacturer Narrative
|
|
Additional information is provided in sections b.5 and h.6.The manufacturer internal reference number is: (b)(4).
|
| |
|
Event or Problem Description
|
|
Additional information received reporting that the event occurred before cataract surgery.The surgery was completed on the same day.
|
| |
|
Additional Manufacturer Narrative
|
|
Additional information is provided in sections d.9, h.3, h.6 and h.11.The company representative was able to confirm the reported events (damaged camera mount and loose handles).To address these issues, the nonconforming video adapter was replaced, and the handle setscrews were secured back into place.The system was tested and found to meet product specifications.A non-conformance based review of the serial number was performed and did not reveal any potential contributing factors to the reported complaint.A manufacturing device history record (dhr) review was performed prior to product release to ensure that the product was manufactured in compliance with the device master record.Based on the assessment, the product met release criteria.A review for complaints reported against this serial number was performed.No similar complaints were reported for the product serial under investigation.The root cause of the reported event is attributed to the nonconforming video adapter and unsecured handle setscrews.How are when the handle setscrews became unsecured is inconclusive.Manufacturer will continue to monitor data for evidence of adverse trending and take further action, as appropriate.The manufacturer internal reference number is: (b)(4).
|
| |
|