| Catalog Number |
0123113 |
| Medical Device Problem Code |
Patient-Device Incompatibility (2682)
|
| Health Effect - Clinical Codes |
Adhesion(s) (1695); Hernia (2240); Bowel Perforation (2668)
|
| Date of Event |
06/02/2009
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
Per information provided: (b)(6) 2009 - patient was diagnosed with multiple incarcerated incisional hernias thereby underwent laparoscopic repair with implant of composix e/x (device #1 & #2).Per op notes, ¿the dense adhesions of abdominal wall to hernia sac were lysed.After lysed all adhesions, the intestine incarcerated in sac was freed.Two composix e/x (device #1 & #2) were placed and tacked.¿ (b)(6) 2009 - patient was diagnosed with intestinal perforation and recurrent incisional hernia thereby underwent open repair with excision of composix (device #1 & #2) and resection of small bowel.Per op notes, ¿the prior mesh (device #1 & #2) was identified and removed.Extensive lysis of adhesions was performed.A small pinhole perforation of the intestine was identified in mid jejunum.That part of intestine was resected.The hernia defect was repaired with sutures.¿ (b)(6) 2009 - patient was diagnosed with ventral hernia thereby underwent open repair with implant of composix mesh (device #3).Per op notes, ¿the hernia sac was identified and excised.The adhesions were lysed.A composix mesh (device #3) was placed using prolene sutures.¿ (b)(6) 2010 - patient was diagnosed with incarcerated recurrent incisional hernia thereby underwent open repair with partial removal of composix mesh (device #3) and implant of composix e/x (device #4).Per op notes, ¿the hernia sac was identified with incarcerated bowel were reduced.The sac was excised.The large prior mesh (device #3) was identified to be bunched up.Some of the mesh was removed.A composix e/x (device #4) was placed and sutured.¿ (b)(6) 2017 - patient was diagnosed with small bowel obstruction with pain and incarcerated incisional hernias x2 thereby underwent laparoscopic converted to open repair with implant of ventralex st (device #5) and synthetic mesh.Per op notes, ¿the extensive lysis of adhesions was performed.The dense adhesions of small bowel and hernias were reduced.The two hernia sacs were identified in right upper quadrant.One is in subcoastal location with multiple loops of small bowel.The prior mesh (device #4) in this region was medially displaced.Another one is in inferior with knuckle of bowel.All the loops of small bowel were reduced and released.All the adhesions of bowel were lysed.The superior defect was repaired using ventralex st (device #5) and sutured.The inferior defect was repaired using synthetic mesh and sutured.¿ (b)(6) 2019 - patient was diagnosed with partial small bowel obstruction and abdominal pain thereby underwent repair with revision surgery.(note: the operative notes are not provided for this procedure).
|
| |
|
Additional Manufacturer Narrative
|
|
Root cause is inconclusive; no conclusion can be made as to the extent to which the implant may have caused or contributed to the patient's postoperative course.This emdr was submitted to represent the bard/davol composix mesh e/x (device #1).An additional emdr submitted to represent the bard/davol composix mesh e/x (device #2 & device #4), ventralex st (device #5) and supplemental emdr was submitted to represent the bard/davol mesh ¿ composix (device #3).Note: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
| |
|
Search Alerts/Recalls
|