| Catalog Number |
60-6085-202A |
| Medical Device Problem Code |
Material Separation (1562)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
07/02/2025
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Reported event of ¿balloon broke off inside the abdomen and the blue and green parts snapped off inside the vagina¿ is confirmed.The device will not be returned for evaluation; however, photographic evidence has been provided.Root cause cannot be determined, however, based ifu; a possible cause of this event could be excessive force.The manufacturing documents from the device history record have been reviewed with special attention to the manufacturing and inspection of the product.The product released for distribution was found to have met all specifications prior to shipment.A two-year lot history review shows a total of 1 device for this lot number and failure mode.A two-year review of complaint history revealed there has been a total of 19 complaints, regarding (b)(4) devices, for this device family and failure mode.During this same time frame (b)(4) devices have been manufactured and shipped worldwide.Should all the complaint devices have been found confirmed for this reported failure, the rate of failure would be (b)(4).Per the instructions for use, the user is advised to re-attach the syringe to the luer connector at the end of the pilot balloon; fully aspirate the air from the intrauterine balloon to deflate.This will allow the intrauterine balloon to be removed from the uterus.Unlock the locking mechanism by turning the thumbscrew counter-clockwise (anti-clockwise) and retract to the handle.A.Swipe a finger around the edge of the vaginal cup to separate the tissue from the cup to prevent tissue damage b.Fully retract the vaginal cup to the handle.Carefully remove the device from the vagina.Do not use excessive force to avoid traumatizing the vaginal canal.We will continue to monitor per regulatory requirements to help ensure patient safety.
|
| |
|
Event or Problem Description
|
|
The customer reported that the that the 60-6085-202a, lg, uterine manipulator device was being used during an unknown procedure on (b)(6) 2025 when it was reported ¿v care that was used today that broke off inside the patient once the uterus had been disconnect from all tissue.The balloon broke off inside the abdomen and the blue and green parts snapped off inside the vagina.Luckily this was noticed, and all broken parts were retrieved.¿.There was no report of injury, medical intervention, or extended hospitalization for the patient or user.This report is being raised due to the reported malfunction with potential for injury upon reoccurrence.
|
| |
|
Search Alerts/Recalls
|
|
|