• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BOSTON SCIENTIFIC CORPORATION WATCHMAN FLX?; SYSTEM, APPENDAGE CLOSURE, LEFT ATRIAL

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BOSTON SCIENTIFIC CORPORATION WATCHMAN FLX?; SYSTEM, APPENDAGE CLOSURE, LEFT ATRIAL Back to Search Results
Model Number M635WU50200
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Thrombosis/Thrombus (4440)
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Quarterly reporting period: q2 2025.Average time to event: 320 days.Device evaluation: under the terms and conditions of the registry, anonymized data was provided.No products were returned as part of the registry.It cannot be determined if these events have been previously reported or if the devices were returned for analysis as part of a previously reported spontaneous complaint.However, the events reported were anticipated in nature as defined by the "potential adverse events" list in the fda-approved instructions for use (ifu).Registry name: watchman flx device watchman flx dapt post approval plan (watchman flx-dapt).
 
Event or Problem Description
This report summarizes 4 serious injury events for thrombosis.Note that multiple event terms may apply to a single patient but are captured separately under reporting guidelines.Device relationship to the events reported is not provided.Of the reported 4 serious injury thrombosis events: 1 was an atrial thrombus 2 were late device thrombosis (30 days - 1 year post implant).1 was a very late device thrombosis (more than 1 year post implant).Age range: 56 to 79 years patient sex: 2 female; 2 male type of procedure: left atrial appendage closure boston scientific received notification of events for the watchman laac device reported in the left atrial appendage occlusion registry (laao) registry, watchman flx dapt clinical study to assess long-term safety and effectiveness outcomes associated with the use and implantation of the watchman flx left atrial appendage (laa) closure device with delivery system in a routine clinical setting.Patient events were reported as event terms with no further detailed information.Multiple event terms may apply to a single patient, but are captured separately under the terms of the summary reporting guidelines.Data includes newly implanted patients and follow up of patients included in the previous data set.Under the terms and conditions of the registry, data is anonymized before being transmitted to bsc, thus there are significant limitations to bsc's ability to correlate the data to information previously reported as a spontaneous complaint.The registry does not provide a causality relationship for each reported event to the device.No further information is available to bsc.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
WATCHMAN FLX?
Common Device Name
SYSTEM, APPENDAGE CLOSURE, LEFT ATRIAL
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
marlborough MA
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
ballybrit business park
galway
EI  
Manufacturer Contact
rachel shields
4100 hamline ave n
arden hills, MN 55112
6512422111
MDR Report Key22555597
Report Number2124215-2025-47374
Device Sequence Number21278244
Product Code NGV
UDI-Device Identifier08714729860488
UDI-Public08714729860488
Combination Product (Y/N)N
Exemption NumberE2017028
Number of Events Summarized4
Summary Report (Y/N)Y
Reporter Type Manufacturer
Initial Reporter Occupation Other
Type of Report Initial
Report Date (Section B) 07/21/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Model NumberM635WU50200
Device Catalogue NumberM635WU50200
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 04/07/2025
Initial Report FDA Received Date07/21/2025
Was Device Evaluated by Manufacturer? (Y/N) No
Is the Device Labeled for Single Use? (Y/N) Yes
Usage of Device A
Patient Sequence Number1
Patient Age71 YR
Patient SexUnknown
-
-