Model Number E163
Medical Device Problem Code Inappropriate/Inadequate Shock/Stimulation (1574)
Health Effect - Clinical Code Shock from Patient Lead(s) (3162)
Date of Event 07/02/2025
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that the healthcare professional (hcp) contacted technical services (ts) regarding a consult transmission from an implantable cardioverter defibrillator (icd).The device detected a rhythm in the ventricular fibrillation (vf) zone and delivered quick convert anti-tachycardia pacing (atp), which briefly terminated the arrhythmia.However, the rhythm spontaneously recurred, prompting the device to initiate charging.Before shock delivery, the rhythm self-terminated, but the shock was committed and delivered while the patient was in normal sinus rhythm.The device accurately sensed the rhythm throughout the episode.The inappropriate shock was attributed to device timing and programming logic.This device remains in service.No additional adverse patient effects were reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
INCEPTA? ICD
Common Device Name
IMPLANTABLE CARDIOVERTER DEFIBRILLATORS (ICD)
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
4100 hamline avenue north
saint paul MN 55112
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
cashel road
clonmel
EI  
Manufacturer Contact
timothy degroot
4100 hamline avenue north
saint paul, MN 55112
6515826168
MDR Report Key22588616
Report Number2124215-2025-49876
Device Sequence Number9052360
Product Code LWP
UDI-Device Identifier00802526480782
UDI-Public(01)00802526480782(17)160624
Combination Product (Y/N)N
Initial Reporter StateTX
Initial Reporter CountryUS
PMA/510(K) Number
P960040
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2014
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Health Professional
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 07/24/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Lay User/Patient
Device Expiration Date06/24/2016
Device Model NumberE163
Device Catalogue NumberE163
Device Lot Number108553
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 07/03/2025
Initial Report FDA Received Date07/24/2025
Date Device Manufactured06/30/2014
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient Age31 YR
Patient SexFemale
-
-