Model Number VP706X-2
Medical Device Problem Code Break (1069)
Health Effect - Clinical Code Insufficient Information (4580)
Date of Event 07/01/2025
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
D10 concomitant products: vp706x-2, srgproii 6-0 30 bl cv-11 da vp706x-2 (lot#:d1b0992y), vp706x-2, srgproii 6-0 30 bl cv-11 da vp706x-2 (lot#:d1b0992y), vp706x-2, srgproii 6-0 30 bl cv-11 da vp706x-2 (lot#:d1b0992y), vp706x-2, srgproii 6-0 30 bl cv-11 da vp706x-2 (lot#:d1b0992y), vp706x-2, srgproii 6-0 30 bl cv-11 da vp706x-2 (lot#:d1b0992y), vp706x-2, srgproii 6-0 30 bl cv-11 da vp706x-2 (lot#:d1b0992y), vp706x-2, srgproii 6-0 30 bl cv-11 da vp706x-2 (lot#:d1b0992y), vp706x-2, srgproii 6-0 30 bl cv-11 da vp706x-2 (lot#:d1b0992y), vp706x-2, srgproii 6-0 30 bl cv-11 da vp706x-2 (lot#:d1b0992y).Medtronic submits this report to comply with fda regulations 21 cfr parts 4 and 803.Medtronic has made reasonable efforts to provide as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.Medtronic will submit a supplemental report if additional relevant information becomes known.
 
Event or Problem Description
According to the reporter during a procedure, the 10 sutures broke in the middle while suturing.Another suture was used to resolve the issue.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SURGIPRO II
Common Device Name
SUTURE, NONABSORBABLE, SYNTHETIC, POLYPROPYLEN
Manufacturer (Section D)
DAVIS & GECK CARIBE LTD
zona franca de san isidro
santo domingo 0101
DR  0101
Manufacturer (Section G)
DAVIS & GECK CARIBE LTD
zona franca de san isidro
santo domingo 0101
DR   0101
Manufacturer Contact
mike bocchino
8200 coral sea st ne
mounds view, MN 55112-4391
8006464633
MDR Report Key22628195
Report Number9612501-2025-02026
Device Sequence Number18219063
Product Code GAW
UDI-Device Identifier10884521758346
UDI-Public(01)10884521758346(17)260131(10)D1B0992Y(20)01
Combination Product (Y/N)N
Initial Reporter CountryTH
PMA/510(K) Number
K010909
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Other,Foreign,Health Professional,Company Representative
Initial Reporter Occupation Other
Type of Report Initial
Report Date (Section B) 07/27/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date01/31/2026
Device Model NumberVP706X-2
Device Catalogue NumberVP706X-2
Device Lot NumberD1B0992Y
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 07/01/2025
Initial Report FDA Received Date07/28/2025
Date Device Manufactured02/09/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
SEE H11.
Patient SexUnknown
-
-