W. L. GORE & ASSOCIATES, INC. GORE® MOLDING & OCCLUSION BALLOON CATHETER; CATHETER, INTRAVASCULAR OCCLUDING, TEMPORARY
|
Back to Search Results |
|
| Catalog Number |
MOB37 |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Code |
Perforation of Vessels (2135)
|
| Date of Event |
07/07/2025
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
H6: the review of the manufacturing paperwork verified that the lot involved in this event met all pre-release specifications.W.L.Gore & associates, inc.(gore) is submitting this report to comply with 21 c.F.R.Part 803, the medical device reporting regulation.This report is based upon information obtained by gore, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Blank fields present on this report include required fields and fields determined to be not applicable.Blank required fields indicate that the information was not provided, was deemed unavailable or was not applicable.This report does not constitute an admission or a conclusion by fda, gore, or its associates that the device, gore or its associates caused or contributed to the event described in the report.In particular, this report does not constitute a legal admission by anyone that the product described in this report has any defects or has malfunctioned, as defined from a legal standpoint.These words are included in the report and are fixed items for selection created by the fda, to categorize the type of event solely for the purpose of reporting pursuant to part 803.This statement should be included with any information or report disclosed to the public under the freedom of information act.
|
| |
|
Event or Problem Description
|
|
The following information was reported to gore: on (b)(6) 2025, this patient underwent endovascular treatment for an abdominal aortic aneurysm using gore® excluder aaa endoprostheses, and gore molding & occlusion balloon catheter as an accessory.A contralateral leg (plc141200j) was deployed towards the right common iliac artery, and an mob balloon was inflated for apposition.Due to a drop in blood pressure, angiography was performed from the distal side, revealing a rupture of the right common iliac artery.The right internal iliac artery was coil embolized, and an additional stent graft was implanted towards the right external iliac artery as a treatment.The patient tolerated the procedure.The physician¿s comment: ¿the patient is elderly, and the vascular was far more fragile than expected.¿.
|
| |
|
Search Alerts/Recalls
|
|
|