• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: LEICA BIOSYSTEMS MELBOURNE PTY. LTD HISTOCORE PELORIS 3 AUTOMATED TISSUE PROCESSOR; PROCESSOR, TISSUE, AUTOMATED

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

LEICA BIOSYSTEMS MELBOURNE PTY. LTD HISTOCORE PELORIS 3 AUTOMATED TISSUE PROCESSOR; PROCESSOR, TISSUE, AUTOMATED Back to Search Results
Model Number HISTOCORE PELORIS 3 AUTOMATED TISSUE PROCESSOR
Medical Device Problem Code Improper or Incorrect Procedure or Method (2017)
Health Effect - Clinical Code Insufficient Information (4580)
Date of Event 07/01/2025
Type of Reportable Event Serious Injury
Event or Problem Description
Leica biosystems received a complaint of poor processing.On (b)(6) 2025, the customer informed the leica field applications specialist (fas) investigating this event with the complainant that, "one case undiagnosable on immunohistochemistry stains.Re-biopsy recommended for this lymph node biopsy case.".
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
HISTOCORE PELORIS 3 AUTOMATED TISSUE PROCESSOR
Common Device Name
PROCESSOR, TISSUE, AUTOMATED
Manufacturer (Section D)
LEICA BIOSYSTEMS MELBOURNE PTY. LTD
495 blackburn road
mount waverley, victoria 3149
AS  3149
MDR Report Key22660806
Report Number3022446399-2025-00008
Device Sequence Number3701798
Product Code IEO
UDI-Device Identifier09349458004811
UDI-Public(01)09349458004811(11)220727
Combination Product (Y/N)N
Initial Reporter StateIL
Initial Reporter CountryUS
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Y
Reporter Type Importer
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date (Section B) 07/29/2025
Report Date (Section F) 07/29/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Model NumberHISTOCORE PELORIS 3 AUTOMATED TISSUE PROCESSOR
Device Catalogue Number45.0005
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? Yes
Distributor Facility Aware Date07/03/2025
Event Location Hospital
Date Report to Manufacturer07/29/2025
Initial Date Received by Manufacturer Not provided
Initial Report FDA Received Date07/29/2025
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient Age65 YR
Patient SexMale
Date Report Sent to FDA07/29/2025
-
-