Catalog Number 02-012-47-3511
Medical Device Problem Code Naturally Worn (2988)
Health Effect - Clinical Code Unspecified Infection (1930)
Date of Event 06/12/2025
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
D10: concomitants: (b)(6) 200-02-35 - three peg patella 35mm.(b)(6) 02-010-04-0335 - logic cr femoral por, right, sz 3.5.(b)(6) 02-012-45-3535 - lgc tibial fit tray cem sz 3.5f / 3.5t.Should additional relevant information be obtained, a follow-up mdr will be submitted accordingly.
 
Event or Problem Description
It was reported that a male patient, who had an initial right knee implanted, underwent a revision procedure approximately 9 years 8 months post the initial procedure.The patient was revised due to a suspected infection.All devices were removed.There were no surgical delays or device breakages reported.The patient was last known to be in stable condition following the event.No x-rays were able to be obtained.The explanted devices are not available for return.The hospital disposed of them.Device images were provided.Prosthesis wear was observed on the explanted liner image.No further information is available.
 
Additional Manufacturer Narrative
This follow-up report is being submitted to relay additional and/or corrected information.The following sections were updated: h6, h11.The following sections were corrected: d1, h6.No device was returned for evaluation; photographs of the device were provided; however, the reported event was unable to be confirmed.The review identified that the articular surface of the tibial insert appears to have minor pitting and wear on the articular surface.The yellowish stained surface is consistent with subsurface damage and there appears to be a minor area of delamination.The wear on the medial side and lateral side appears consistent with bone or cement overhang from the sides of the femoral component.The explanted femoral component and tibial tray show residual bone cement and biological material adhering to the bone contacting surfaces of these components.Operative notes and/or medical records were not provided for review of usage/ technique.A review of complaint history determined that no further action is required as no trends were identified.A definitive root cause was unable to be determined; however, may have resulted from the reported infection or due to the inclusion of the polyethylene in the packaging recall.The prosthesis wear appears minor and was likely not the root cause of the revision.The cause for the infection could not be confirmed from the provided information.If any further information is obtained that would change or alter any information provided, a supplemental report will be filed accordingly.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
LOGIC CR TIB INSERT STD, SZ 3.5, 11 MM
Common Device Name
PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL
Manufacturer (Section D)
EXACTECH, INC.
2320 nw 66 court
gainesville FL 32653
Manufacturer (Section G)
EXACTECH, INC.
2320 nw 66 court
gainesville FL 32653
Manufacturer Contact
geoff gannon
2320 nw 66 court
gainesville, FL 32653
3525541928
MDR Report Key22669893
Report Number1038671-2025-02642
Device Sequence Number7767757
Product Code JWH
UDI-Device Identifier10885862159250
UDI-Public10885862159250
Combination Product (Y/N)N
Initial Reporter CountryAS
PMA/510(K) Number
K111400
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2015
Device Explanted Year2025
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 10/20/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date06/06/2022
Device Catalogue Number02-012-47-3511
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 07/07/2025
Supplement Date Received by Manufacturer10/17/2025
Initial Report FDA Received Date07/30/2025
Supplement Report FDA Received Date10/20/2025
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured06/09/2014
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient SexMale
-
-