TERUMO CARDIOVASCULAR SYSTEMS CORPORATION VIRTUOSAPH PLUS WITH RADIAL INDICATION; ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES Back to Search Results
Model Number VSP550EX
Medical Device Problem Code Defective Device (2588)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 07/11/2025
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Terumo will not receive the device for evaluation; however, the investigation has yet to be completed.Terumo plans on submitting a follow-up report when the investigation is complete and when more information becomes available.For this reason, terumo references evaluation conclusion code 11.
 
Event or Problem Description
The user facility reported to terumo cardiovascular that during vein harvesting procedure, the harvester pin for the basket slipped causing a tear in the vein.As per the user facility, the locking mechanism with the green button was fully pushed in, but the pin seemed to be loose and not keeping it locked.Basically, the pin on the v-keeper did not close all the way, even though it was fully in position and allowed the vein to be damaged.No known consequence or health impact to patient.Product was changed out.Procedure completed successfully.
 
Additional Manufacturer Narrative
This follow-up report is submitted to fda in accord with applicable regulations ¿ and as indicated by terumo cardiovascular systems in the initial report submitted to the fda on august 1,2025.Upon further investigation of the reported event, the following information is new and/or changed: g3 (date received by manufacturer).G6 (indication that this is a follow-up report).H2 (follow-up due to additional information).H6 (identification of evaluation codes 11, 3331, 4114, 3221, 4315).The affected sample was not returned for evaluation.A retention sample from the same lot number was inspected to show no anomalies with the device.All electrical circuits were measured, and the electrical resistances were found to be stable and within the product specifications.The retention sample was also tested in combination with the olympus tower and used to cut veins in a syndaver with no issues.Without the returned device, a thorough investigation could not be performed, and a definitive root cause could not be determined.All available information has been placed on file in quality management for appropriate tracking, trending, and follow-up.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
VIRTUOSAPH PLUS WITH RADIAL INDICATION
Common Device Name
ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES
Manufacturer (Section D)
TERUMO CARDIOVASCULAR SYSTEMS CORPORATION
125 blue ball road
elkton MD 21921
Manufacturer (Section G)
SAME
Manufacturer Contact
douglas patton
125 blue ball road
elkton, MD 21921
7346634145
MDR Report Key22687403
Report Number1124841-2025-00063
Device Sequence Number12984805
Product Code GEI
UDI-Device Identifier00699753450769
UDI-Public(01)00699753450769(17)270630(10)47K
Combination Product (Y/N)N
Initial Reporter StateNC
Initial Reporter CountryUS
PMA/510(K) Number
K160206
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Health Professional,User Facility,Company Representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 10/03/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberVSP550EX
Device Catalogue NumberN/A
Device Lot Number47K
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 07/11/2025
Supplement Date Received by Manufacturer09/09/2025
Initial Report FDA Received Date08/01/2025
Supplement Report FDA Received Date10/03/2025
Was Device Evaluated by Manufacturer? (Y/N) No
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient SexUnknown
-
-