This report is being submitted pursuant to the provisions of 21 cfr, part 803 (and/or part 4, as applicable).This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by depuy synthes, or its employees that the report constitutes an admission that the product, depuy synthes, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.
|
|
It was reported that patient underwent the primary surgery (l1/l5) on an unknown date.The surgery was completed successfully without any surgical delay.After surgery, it was confirmed that the l1 screw had loosened.On (b)(6) 2025, revision surgery was performed and the l1 screw was removed.When the surgeon removed the l1 screw, it was found to have broken off at the transverse hole.The surgeon determined that there was no problem as part of the screw was still retained in the cement and then continued with the surgery.The surgery was completed successfully without any surgical delay.Patient was stable.
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If the information is unknown, not available or does not apply, the section/field of the form is left blank.H11 additional narrative: h3, h6: an analysis of the product could not be performed since a physical sample was not received for evaluation.As part of our company quality system process, all devices are manufactured, inspected, and distributed to approved specifications.Based on the information available, there is no indication that a design or manufacturing issue has caused the reported complaint condition, therefore it has been determined that no corrective and preventive action is required at this time.Additional complaint information monitoring for potential safety signals will be conducted through complaint trending as part of the post-market surveillance.However, if the product is received at a later date, the investigation will be updated as applicable.Device history review a dhr evaluation was performed for the finished device product code: 186745440s lot number: tbaliq.It was electronically reviewed and no nonconformances / manufacturing irregularities were identified during the manufacturing process.The product was released on: 14 jun 2023 manufacturing site: jabil le locle.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.
|