| Catalog Number |
47525300M |
| Medical Device Problem Code |
Burst Container or Vessel (1074)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
07/17/2025
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Additional information is pending and will be submitted within 30 days upon receipt.
|
| |
|
Event or Problem Description
|
|
As reported, a 2.5mm x 300mm saberx percutaneous transluminal angioplasty (pta) balloon catheter ruptured when pressure was increased to 5 atmospheres (atm).A new 2.5mm x 300mm saberx pta balloon catheter was opened and was dilated above 6 atm without issue.There were no reported injuries to the patient.This was during a procedure to treat a below the knee (btk) lesion in which an ipsilateral puncture was made.A non-cordis guidewire was inserted prior to use of the initial saberx.014 pta balloon catheter.The device will not be returned.Additional information was requested; however, the information was not obtained after multiple attempts.
|
| |
|
Event or Problem Description
|
|
As reported, a 2.5mm x 300mm saberx percutaneous transluminal angioplasty (pta) balloon catheter ruptured when pressure was increased to 5 atmospheres (atm).A new 2.5mm x 300mm saberx pta balloon catheter was opened and was dilated above 6 atm without issue.There were no reported injuries to the patient.This was during a procedure to treat a below the knee (btk) lesion in which an ipsilateral puncture was made.A non-cordis guidewire was inserted prior to use of the initial saberx.014 pta balloon catheter.The device will not be returned.Additional information was requested; however, the information was not obtained after multiple attempts.
|
| |
|
Additional Manufacturer Narrative
|
|
As reported, a 2.5mm x 300mm saberx percutaneous transluminal angioplasty (pta) balloon catheter ruptured when pressure was increased to 5 atmospheres (atm).A new 2.5mm x 300mm saberx pta balloon catheter was opened and was dilated above 6 atm without issue.There were no reported injuries to the patient.This was during a procedure to treat a below the knee (btk) lesion in which an ipsilateral puncture was made.A non-cordis guidewire was inserted prior to use of the initial saberx.014 pta balloon catheter.Additional information was requested; however, the information was not obtained after multiple attempts.The product was not returned for analysis.A review of the manufacturing documentation associated with lot 2502103090 presented no issues during the manufacturing process that can be related to the reported event.Based on the limited information provided, it is not possible to draw a conclusion about a clinical relationship between the device and the event.Without the return of the device for analysis, the reported customer complaint ¿balloon burst at/below rbp¿ could not be evaluated.Without the return of the device, and with no procedural films, the exact cause of the reported event could not be determined.Unspecified procedural, handling, and/or anatomical factors may have contributed to the reported issue.According to the warnings in the safety information in the instructions for use, ¿prior to angioplasty, the catheter should be examined to verify functionality and integrity, and ensure that its size and shape are suitable for the specific procedure for which it is to be used.Do not use if product damage is suspected or evident.To reduce the potential for vessel damage or the risk of dislodgement of particles it is very important that the inflated diameter of the balloon should approximate the diameter of the vessel just proximal and distal to the lesion.The balloon dimensions are printed on the product label.The compliance table incorporated with the product shows how balloon diameter increases as pressure increases.Do not exceed the rated burst pressure recommended on the label.The rated burst pressure is based on the results of in vitro testing.At least 99.9% of the balloons (with a 95% confidence) will not burst at or below their rated burst pressure.Use of a pressure monitoring device is recommended to prevent over-pressurization.Pressure in excess of the rated burst pressure can cause balloon rupture and potential inability to withdraw the catheter through the introducer sheath.Balloon rupture can cause vessel damage and the need for additional intervention.Use only the recommended balloon inflation medium (a 50/50 mixture by volume of contrast medium and normal saline).Never use air or any gaseous medium to inflate the balloon.¿based on the information available for review, there is no indication to suggest that the reported failure could be related to the design or manufacturing process of the unit.Therefore, no corrective/preventative actions will be taken at this time.
|
| |
|