| Catalog Number |
0117320 |
| Medical Device Problem Code |
Material Split, Cut or Torn (4008)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
07/29/2025
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
As reported, the edge of 3dmax light mesh was found to be cracked.The physical sample has been received for evaluation.Review of the returned sample is currently ongoing, as such no conclusions have been made.When the sample evaluation is completed, a supplemental mdr will be submitted.Review of the manufacturing records was performed and found the lot was manufactured to specification.To date this is the only reported complaint for this lot of (b)(4) units released for distribution.Note: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
| |
|
Event or Problem Description
|
|
As reported, during laparoscopic inguinal hernia repair (tapp) procedure the edge of 3dmax light mesh was found to be cracked.It was reported that 12mm trocar was used for the procedure.The procedure was completed with another device.There was no patient injury.
|
| |
|
Additional Manufacturer Narrative
|
|
As reported, the edge of 3dmax light mesh was found to be cracked.The physical sample has been received for evaluation.Review of the returned sample is currently ongoing, as such no conclusions have been made.When the sample evaluation is completed, a supplemental mdr will be submitted.Review of the manufacturing records was performed and found the lot was manufactured to specification.To date this is the only reported complaint for this lot of (b)(4) units released for distribution.Addendum: this is an addendum to the initial mdr submitted.This supplemental mdr is submitted to document the sample evaluation results.The sample evaluation confirms there is crack/tear in the edge seal of the 3dmax light mesh.Based on returned sample evaluation performed, the reported condition is confirmed as manufacturing related.Awareness notification was provided to all appropriate manufacturing personnel on event reported, to emphasize the importance of product handling and inspection during manufacturing process.Updated fields: b4, g3, g6, h2, h3, h6, h10.Note: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
| |
|
Event or Problem Description
|
|
As reported, during laparoscopic inguinal hernia repair (tapp) procedure the edge of 3dmax light mesh was found to be cracked.It was reported that 12mm trocar was used for the procedure.The procedure was completed with another device.There was no patient injury.
|
| |
|