Catalog Number IAV08006008P
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Codes Stenosis (2263); Insufficient Information (4580)
Date of Event 04/27/2023
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Medtronic submits this report to comply with fda regulations 21 cfr parts 4 and 803.Medtronic has made reasonable efforts to provide as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.Medtronic will submit a supplemental report if additional relevant information becomes known.
 
Event or Problem Description
During the index procedure 4 in.Pact av access balloon catheters were used to treat the venous outflow, brachiocephalic/superior vena cava (svc) stent and the cephalic arch of the right arm.Approximately 6 months post procedure the patient suffered from central vein restenosis of the avf.The patient presented for a routine fistulogram which showed restenosis in the central vein (non-index lesion).The event was successfully treated with a high pressure and plain balloon angioplasty.During the percutaneous intervention, the in-cannulation zone, central vein and venous outflow of the right arm were also treated using non-medtronic balloons.The patient was also treated with medication.The patient recovered.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
IN.PACT AV ACCESS
Common Device Name
DRUG-COATED PERIPHERAL TRANSLUMINAL ANGIOPLAST
Manufacturer (Section D)
MEDTRONIC IRELAND
parkmore business park west
galway
EI 
Manufacturer (Section G)
MEDTRONIC IRELAND
parkmore business park west
galway
EI  
Manufacturer Contact
alison sweeney
parkmore business park west
galway 
EI  
091708096
MDR Report Key22861575
Report Number9612164-2025-04130
Device Sequence Number20745812
Product Code PRC
UDI-Device Identifier00763000232658
UDI-Public(01)00763000232658(17)250529(10)0011236924
Combination Product (Y/N)N
Initial Reporter StateNJ
Initial Reporter CountryUS
PMA/510(K) Number
P190008
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Study,Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 08/21/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date05/29/2025
Device Catalogue NumberIAV08006008P
Device Lot Number0011236924
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 07/26/2025
Initial Report FDA Received Date08/21/2025
Date Device Manufactured05/30/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Other; Required Intervention;
Patient Age58 YR
Patient SexMale
Patient Weight69 KG
Patient EthnicityNon Hispanic
Patient RaceAsian
-
-