MENTOR TEXAS MENTOR MEMORYSHAPE BREAST IMPLANT; PROSTHESIS, BREAST, NONINFLATABLE, INTERNAL, SILICONE GEL-FILLED
|
Back to Search Results |
|
| Catalog Number |
3341307 |
| Medical Device Problem Codes |
Gel Leak (1267); Material Rupture (1546)
|
| Health Effect - Clinical Code |
Deformity/ Disfigurement (2360)
|
| Date of Event |
01/01/2025
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
Since the device has not been returned for analysis, no product failure analysis can be conducted, and no determination of possible contributing factors can be made.As such, the investigation will be closed.If the complaint device is received in the future, the investigation will be reopened and conducted as appropriate.A manufacturing record evaluation (mre) was performed, and no anomalies were found related to this complaint.In addition, the mre verifies that the device was manufactured in accordance with documented specification and procedures.Reason for device explant and/or reoperation: rupture, gel bleed.Date of explantation: (b)(6) 2025.Mentor is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which mentor has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, mentor, or its employees that the report constitutes an admission that the device, mentor, or its employees caused or contributed to the potential event described in this report.If certain information is unknown, not available or does not apply, the section/field of the form is left blank.Manufacturer¿s reference number: (b)(4).
|
| |
|
Event or Problem Description
|
|
It was reported that a patient underwent a primary breast augmentation surgery with implantation of a 370cc mentor memoryshape breast implant prosthesis.Post-operatively, the patient had concerns of a bulge on the right side.Ultrasound imaging was conducted and she was diagnosed with a ruptured right implant with gel bleed.As a result, the patient was scheduled for implant removal on (b)(6) 2025.The date of event was provided to mentor as a best estimate.Follow-ups have been conducted, and no additional information has been received.If more information becomes available, mentor will submit a supplemental report accordingly.
|
| |
|
Additional Manufacturer Narrative
|
|
On september 22, 2025, the mentor analysis lab received the suspect medical device for evaluation.On (b)(6) 2025, mentor was notified that a biopsy of right anterior capsule was performed during the surgery.Additionally, the patient underwent bilateral exchange with mentor gel implants.On october 13, 2025, mentor completed an evaluation on the returned device.Device evaluation: mentor conducted a visual inspection, leak testing, and microscopic examination of the device.Visual analysis of the returned device revealed that the breast implant had an area of missing material on the posterior view, measuring approximately 1.5 cm x 1.0 cm.Leak testing was performed, according to mentor procedure, and no additional areas of gel exposure were found.Microscopic examination was performed, and the cause of the missing material could not be identified.Although no conclusion could be reached on the cause of the reported event, the instructions for use contain the following caution: rupture can occur at any time after implantation, but it is more likely to occur the longer the implant is implanted.The following things may cause implant to rupture: damage by surgical instruments; stressing the implant during implantation and weakening it; folding or wrinkling of the implant shell; excessive force to the chest (e.G.During closed capsulotomy); trauma; compression during mammographic imaging; and severe capsular contracture.Breast implants may also simply wear out over time.Manufacturer¿s reference number: (b)(4).
|
| |
|
Search Alerts/Recalls
|
|
|