• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: TERUMO BCT SPECTRA OPTIA; SPECTRA OPTIA EXCHANGE SET

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

TERUMO BCT SPECTRA OPTIA; SPECTRA OPTIA EXCHANGE SET Back to Search Results
Catalog Number 4122201
Medical Device Problem Codes No Apparent Adverse Event (3189); Insufficient Device Problem Information (3190)
Health Effect - Clinical Codes Hypersensitivity/Allergic reaction (1907); No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 06/22/2025
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Lot number, manufacture date and expiry date are not available at this time.Investigation is in process, a follow-up report will be provided.Icitation: srivaths, p., monis, g.F., fernando, l.P., hendrickson, j.E., raval, j.S., jacquot, c., davis, k., wong, e., & yamada, c.(2025).Report of the asfa apheresis registry study on focal segmental glomerulosclerosis.Journal of clinical apheresis, 40(4).Https://doi.Org/10.1002/jca.70041.
 
Event or Problem Description
Per journal article "report of the asfa apheresis registry study on focal segmental glomerulosclerosis" by poyyapakkam srivaths, grace f.Monis, leonor p.Fernando, jeanne e.Hendrickson, jay s.Raval, cyril jacquot, keefe davis, edward wong, chisa yamad abstract focal segmental glomerulosclerosis (fsgs) is one of the causes of end-stage kidney disease.The etiology is not fully understood, and standardized treatments are not established.We created a registry on apheresis for post-transplant fsgs through the renal subcommittee in the research committee in the american society for apheresis (asfa), and here is our first report.Members of the renal subcommittee from seven centers in the united states contributed data collection on demographic, clinical course, and overall outcomes of patients with post-transplant recurrence of fsgs treated with therapeutic plasma exchange (tpe) between 2015 and 2020.The tpe data, including frequency and replacement fluid for tpe, are also investigated.The median age at diagnosis of fsgs and first transplantation among 26 patients was 12.7 and 21 years, respectively.The fsgs recurred at a median of 1 day after transplantation, and tpe was performed daily or every other day in the first month and continued at some frequency beyond a year in some cases.Most procedures used albumin as a replacement fluid and citrate anticoagulation, with 1¿1.5 plasma volumes exchange.Twelve patients had complete/partial remission by 6 months.The median urine protein/creatinine ratio improved from 4.47 to 1.4 mg/mg within 3 months, and egfr improved from 26 to 78 ml/min/1.73 m2 in a year after tpe started.The study revealed some uniformity in the prescription of tpe, primarily using albumin as replacement fluid and performing 1¿1.5 plasma volume exchanges.Observed complication rates were minimal.Tpe can be one of the treatments to consider in this condition.Most patients tolerated tpe well.There were two instances of allergic reactions with plasma replacement, two instances of suspected transfusion reactions, and three instances of asymptomatic hypocalcemia in the first 4 weeks of treatment.Most patients tolerated tpe well, with fewer than 2% of patients having allergic reactions or suspected transfusion reactions and about 2% of patients having only biochemical hypocalcemia from citrate toxicity.Specific details, such as patient information and outcome, were not included in the article for these events, therefore this report is being provided as a summary of the events.It is unknown at this time if medical intervention was required for these events the collection set is not available for return because it was discarded by the customer.
 
Event or Problem Description
Per journal article "report of the asfa apheresis registry study on focal segmental glomerulosclerosis" by poyyapakkam srivaths, grace f.Monis, leonor p.Fernando, jeanne e.Hendrickson, jay s.Raval, cyril jacquot, keefe davis, edward wong, chisa yamad abstract: focal segmental glomerulosclerosis (fsgs) is one of the causes of end-stage kidney disease.The etiology is not fully understood, and standardized treatments are not established.We created a registry on apheresis for post-transplant fsgs through the renal subcommittee in the research committee in the american society for apheresis (asfa), and here is our first report.Members of the renal subcommittee from seven centers in the united states contributed data collection on demographic, clinical course, and overall outcomes of patients with post-transplant recurrence of fsgs treated with therapeutic plasma exchange (tpe) between 2015 and 2020.The tpe data, including frequency and replacement fluid for tpe, are also investigated.The median age at diagnosis of fsgs and first transplantation among 26 patients was 12.7 and 21 years, respectively.The fsgs recurred at a median of 1 day after transplantation, and tpe was performed daily or every other day in the first month and continued at some frequency beyond a year in some cases.Most procedures used albumin as a replacement fluid and citrate anticoagulation, with 1¿1.5 plasma volumes exchange.Twelve patients had complete/partial remission by 6 months.The median urine protein/creatinine ratio improved from 4.47 to 1.4 mg/mg within 3 months, and egfr improved from 26 to 78 ml/min/1.73 m2 in a year after tpe started.The study revealed some uniformity in the prescription of tpe, primarily using albumin as replacement fluid and performing 1¿1.5 plasma volume exchanges.Observed complication rates were minimal.Tpe can be one of the treatments to consider in this condition.Most patients tolerated tpe well.There were two instances of allergic reactions with plasma replacement, two instances of suspected transfusion reactions, and three instances of asymptomatic hypocalcemia in the first 4 weeks of treatment.Most patients tolerated tpe well, with fewer than 2% of patients having allergic reactions or suspected transfusion reactions and about 2% of patients having only biochemical hypocalcemia from citrate toxicity.Specific details, such as patient information and outcome, were not included in the article for these events, therefore this report is being provided as a summary of the events.It is unknown at this time if medical intervention was required for these events the collection set is not available for return because it was discarded by the customer.
 
Additional Manufacturer Narrative
This report is being filed to provide additional information in h.6 and h.11.Investigation: further evaluation of this event has determined that the device did not cause or contribute to a death or serious injury, nor is there a likely potential for death or serious injury associated with this event based on additional investigational information.It was confirmed that there is no allegation against a tbct device.No further reporting will be provided as this does not represent a reportable event.Lot number, manufacture date and expiry date are not available at this time.Citation: srivaths, p., monis, g.F., fernando, l.P., hendrickson, j.E., raval, j.S., jacquot, c., davis, k., wong, e., & yamada, c.(2025).Report of the asfa apheresis registry study on focal segmental glomerulosclerosis.Journal of clinical apheresis, 40(4).Https://doi.Org/10.1002/jca.70041.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SPECTRA OPTIA
Common Device Name
SPECTRA OPTIA EXCHANGE SET
Manufacturer (Section D)
TERUMO BCT
lakewood CO 80215
Manufacturer (Section G)
TERUMO BCT
10810 w. collins ave
lakewood CO 80215
Manufacturer Contact
scot hilden
10810 w. collins ave
lakewood, CO 80215
MDR Report Key22885475
Report Number1722028-2025-00194
Device Sequence Number8918725
Product Code LKN
UDI-Device Identifier05020583122208
UDI-Public05020583122208
Combination Product (Y/N)N
Initial Reporter StateTX
Initial Reporter CountryUS
PMA/510(K) Number
K183081
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Literature
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 08/25/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Catalogue Number4122201
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 08/01/2025
Supplement Date Received by Manufacturer02/25/2026
Initial Report FDA Received Date08/25/2025
Supplement Report FDA Received Date02/26/2026
Was Device Evaluated by Manufacturer? (Y/N) No
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient SexUnknown
-
-