SMITH & NEPHEW, INC. BIOINDUCTIVE IMPLANT W/ARTH DEL MED; MESH, SURGICAL, COLLAGEN, ORTHOPAEDICS, REINFORCEMENT OF TENDON
|
Back to Search Results |
|
| Catalog Number |
4565 |
| Medical Device Problem Code |
Detachment of Device or Device Component (2907)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
07/28/2025
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
H11: internal complaint reference: (b)(4).H3, h6: this complaint was opened by smith+nephew to document a product problem associated with a smith+nephew device.The reported problem relates to known inherent device and/or procedural risks that are appropriately documented in our risk files.Smith+nephew will continue to monitor trends in accordance with our post-market surveillance process and take necessary action as required if anticipated severity and/or occurrence rates are exceeded.Smith+nephew has no reason to suspect that the product failed to meet any specifications at the time of manufacture.Based on our review of all currently available information, we are unable to identify a definitive root cause.However, as the use of our product cannot be excluded as a potential cause or contributory factor to the reported issue, we are conservatively submitting this report in accordance with applicable regulations.If additional investigative findings or information becomes available that alters the conclusions of this report, a follow-up report will be submitted as required.
|
| |
|
Event or Problem Description
|
|
It was reported that during an arthroscopy, once the bioinductive implant was deployed, the distal portion of the deployment with the metal brackets was completely disconnected from the proximal side of the junction of the device.The procedure was completed with the same reported device, once the distal section came off the inserter, the surgeon was able to salvage the implant.The implant was separated from the metal butterfly deployment wings with a grasper, along with the plastic that it was connected to, then it was successfully implanted after removing all other objects.No delay or further complications were reported.
|
| |
|
Additional Manufacturer Narrative
|
|
H2: additional information on a1, b5 & h6 (type of investigation).
|
| |
|
Event or Problem Description
|
|
It was reported that during an arthroscopy, once the bioinductive implant was deployed, the distal portion of the deployment with the metal brackets was completely disconnected from the proximal side of the junction of the device.The procedure was completed with the same reported device, once the distal section came off the inserter, the surgeon was able to salvage the implant.The implant was separated from the metal butterfly deployment wings with a grasper, along with the plastic that it was connected to, then it was successfully implanted after removing all other objects.No delay or further complications were reported.Patient is recovering.
|
| |
|