Model Number ANGEL PRP SYSTEM CENTRIFUGE US (NEW)
Medical Device Problem Code Use of Device Problem (1670)
Health Effect - Clinical Code Insufficient Information (4580)
Date of Event 08/11/2025
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Investigation is in process.A follow-up report will be provided upon availability of additional information.
 
Event or Problem Description
On 08/12/2025, a sales representative reported via (b)(4) that an abs-10060 angel centrifuge kept giving an insufficient fill error - there was plenty of blood in the machine.This occurred during an ankle fusion with prp for the bone graft; they ended up having to abort the procedure, and the disk was stuck in the machine afterward.They had several people try to get the disk out with no luck.We were able to finish the case but did not end up using prp to mix with bone graft; the doctor pulled whole blood instead.Additional information was provided on 08/19/2025 via phone, where it was confirmed that the procedure itself was not aborted; however, the prp portion of it was.They continued the case by redrawing blood and mixing it with the bone graft.The disc that became stuck was an abs-10061t.
 
Additional Manufacturer Narrative
Additional information: d9, g3, h3, h6.The complaint allegation is confirmed by the attached pictures from the alc decontamination department.They showed blood around the tubing, bag, and disk of the angel processing set and blood drainage from the disk/tubing into the rotor housing of the angel system.Based on the information provided, which may include the device (if available and returned), pictures, videos, event description, and any additional information from the field, arthrex was able to conclude a most likely cause.The most likely cause for the reported failure can be attributed to user error of the device due to the misalignment of insertion/and or improper seating of the angel processing set.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ANGEL PRP SYSTEM CENTRIFUGE US (NEW)
Common Device Name
CENTRIFUGE
Manufacturer (Section D)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer (Section G)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer Contact
jared engle
8009337001
MDR Report Key22940130
Report Number1220246-2025-03697
Device Sequence Number9800987
Product Code ORG
UDI-Device Identifier00888867083974
UDI-Public(01)00888867083974(11)200625(10)11167431
Combination Product (Y/N)N
Initial Reporter StateAZ
Initial Reporter CountryUS
PMA/510(K) Number
BK110046
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Company Representative
Initial Reporter Occupation Administrator/Supervisor
Type of Report Initial,Followup
Report Date (Section B) 09/30/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberANGEL PRP SYSTEM CENTRIFUGE US (NEW)
Device Catalogue NumberABS-10060
Device Lot Number11167431
Was Device Available for Evaluation? Device Returned to Manufacturer
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 08/12/2025
Supplement Date Received by Manufacturer09/26/2025
Initial Report FDA Received Date09/02/2025
Supplement Report FDA Received Date09/30/2025
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured06/25/2020
Is the Device Labeled for Single Use? (Y/N) No
Usage of Device Reuse
Patient Sequence Number1
Patient SexUnknown
-
-