• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BOSTON SCIENTIFIC CORPORATION JETSTREAM? SC; CATHETER, PERIPHERAL, ATHERECTOMY

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BOSTON SCIENTIFIC CORPORATION JETSTREAM? SC; CATHETER, PERIPHERAL, ATHERECTOMY Back to Search Results
Model Number 112262-001
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Codes Hemorrhage/Blood Loss/Bleeding (1888); Perforation of Vessels (2135)
Date of Event 08/05/2025
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported vessel dissection perforation, and an additional device was required.A 1.85mm jetstream sc catheter was chosen to treat a 95% stenosed, moderately tortuous and calcified target lesion with intermittent claudication in the right superficial femoral artery (sfa).Prior to the procedure, the patient experienced pain and vessel occlusion.During the procedure, 1.85mm jetstream sc catheter functioned as expected; however, a vessel perforation occurred that resulted from cutting too close to the blood vessel wall.The perforation resulted in internal bleeding, and a non-boston scientific stent was placed.The procedure was completed with another device of a different model.There were no further patient complications as a result of the event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
JETSTREAM? SC
Common Device Name
CATHETER, PERIPHERAL, ATHERECTOMY
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer (Section G)
BOSTON SCIENTIFIC LIMITED
cork T12 Y K88
EI   T12 YK88
Manufacturer Contact
rachel shields
4100 hamline ave n
arden hills, MN 55112
6512422111
MDR Report Key22952388
Report Number2124215-2025-61759
Device Sequence Number9591535
Product Code MCW
UDI-Device Identifier08714729889861
UDI-Public(01)08714729889861
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
K133023
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Other,Foreign,Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 09/03/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Model Number112262-001
Device Catalogue Number112262-001
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 08/05/2025
Initial Report FDA Received Date09/03/2025
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age83 YR
Patient SexMale
Patient Weight48 KG
-
-