|
G5.Multiple pma / 510(k)#: k020322, k022129, k023444, k023634, k023858, k024153, k031530, k031699, k031912, k032299, k032567, k032655, k033362, k033560, k041384, k042932, k052269, k060214, k060217, k060257, k060444, k060447, k061327, k061355, k062207, k062944, k063301, k063486, k063573, k063811, k063824, k071623, k132674, k132909, k151320, k181665, k173252, k190905, k163637, k173523, k033458, and k123266.Investigation summary this complaint is for high mic meropenem (mem) and ertapenem (etp) with citrobacter when using phoenix panel nmic-306 (catalog number 449292) batch number 4100303.The customer did not provide isolates or panel returns but provided phoenix generated lab reports for the investigation.The lab reports show high mic mem and etp with citrobacter when using the complaint batch.To investigate, three retention panels from the complaint batch were inoculated with in house isolate citrobacter freundii enf 10852 then placed in a phoenix m50 for mem and etp mic results.In addition, two control panels from the same material but different batch were inoculated with in house isolate citrobacter freundii enf 10852 then placed in a phoenix m50 for mem and etp mic results.Results of the investigation returned all panels with the expected mic for mem and etp.This complaint is not confirmed.The batch history record was satisfactory and no quality notifications were generated during manufacturing and inspection.Complaint trending was performed and no trends were identified associated with this defect.Bd will continue to monitor for trends and take action as necessary.Please continue to communicate any additional concerns.This mdr is being submitted as part of a retrospective review of records dating april 2023-2025, under capa 11910483.
|