| Model Number |
CDS0706-NTW |
| Medical Device Problem Codes |
Difficult or Delayed Positioning (1157); Device Damaged by Another Device (2915); Physical Resistance/Sticking (4012)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
08/14/2025
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
Na.The device remains implanted in patient.The device will not be returned for evaluation.Investigation is not yet complete.A follow-up report will be submitted with all additional relevant information.
|
| |
|
Event or Problem Description
|
|
It was reported on (b)(6) 2025 that the patient presented with grade 4+ functional mitral regurgitation (mr) and dilated left and right ventricle for a mitraclip procedure.During the procedure, one mitraclip was successfully implanted.Following deployment of a second mitraclip xtw, mitral regurgitation (mr) worsened.A third mitraclip ntw was attempted; however, resistance was encountered while advancing the clip lateral to the xtw.Fluoroscopy revealed entanglement between the ntw and xtw clips.During troubleshooting, it was observed that the xtw grippers were not engaged with the leaflets, and its gripper assembly remained intact with the distal end of the ntw, contributing to the entanglement.Single leaflet device attachment (slda) of the xtw clip from the anterior leaflet occurred during the disentanglement process.The ntw clip was successfully deployed with adequate leaflet grasp.An atrial septal defect (asd) had occurred.Patient experienced hypoxia.A non-abbott device was used for asd closure.The patient was placed on intra-aortic balloon pump (iabp) support in intensive care unit (icu).Post-procedure, mr was reduced to grade 3+.There was no clinically significant procedural delay.No additional information was provided.
|
| |
|
Event or Problem Description
|
|
It was reported on (b)(6) 2025 that the patient presented with grade 4+ functional mitral regurgitation (mr) and dilated left and right ventricle for a mitraclip procedure.During the procedure, one mitraclip was successfully implanted.Following deployment of a second mitraclip xtw, mitral regurgitation (mr) worsened.A third mitraclip ntw was attempted; however, resistance was encountered while advancing the clip lateral to the xtw.Fluoroscopy revealed entanglement between the ntw and xtw clips.During troubleshooting, it was observed that the xtw grippers were not engaged with the leaflets, and its gripper assembly remained intact with the distal end of the ntw, contributing to the entanglement.Single leaflet device attachment (slda) of the xtw clip from the anterior leaflet occurred during the disentanglement process.The ntw clip was successfully deployed with adequate leaflet grasp.A atrial septal defect (asd) had occurred.Patient experienced hypoxia.A non-abbott device was used for asd closure.The patient was placed on intra-aortic balloon pump (iabp) support in intensive care unit (icu).Post-procedure, mr was reduced to grade 3+.There was no clinically significant procedural delay.No additional information was provided.
|
| |
|
Additional Manufacturer Narrative
|
|
The device was not returned for analysis.A review of the lot history record revealed no manufacturing nonconformities issued to the reported lot that would have contributed to this event.Additionally, a review of the complaint history identified no similar complaints reported from this lot.Based on available information, the reported difficult or delayed positioning and device damaged by another device (caused damage) appeared to be related to procedural conditions.A cause for the reported physical resistance/sticking could not be determined.The reported unexpected medical intervention was a result of case-specific circumstance.There is no indication of a product issue with respect to manufacture, design or labeling.
|
| |
|