Model Number SET-0013-1
Medical Device Problem Codes Leak/Splash (1354); No Apparent Adverse Event (3189)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 04/19/2024
Type of Reportable Event Malfunction
Event or Problem Description
The following has been reported: a set was reported to leak from the secondary inlet port during priming.The connector was reported to be "very loose and came off." there was no patient harm and no delay in infusion.There was no hazardous materials in the set.A preliminary review of the logs could not be performed.One sample of ivenix administration set was returned for evaluation.During the visual inspection it was observed that the secondary port was separated from the set as reported by the customer.It was not possible to install the unit into the ivenix machine as the secondary port was loose and separated from port.The customer complaint is confirmed.Probable root cause of reported failure could be related to the supplier manufacturing process.It is possible that the secondary port was not assembled correctly causing the unit to be separated from cassette.The supplier opened a complaint to investigate this issue.Fresenius kabi has performed a retrospective review of complaints associated with this failure mode and has decided to submit an mdr as a conservative measure.No adverse effects were reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
IVENIX, INC.
Common Device Name
LVP PRIMARY ADMINISTRATION SET, DUAL-INLET, LOW-SORBING, NEEDLE-FREE PORT, Y-SIT
Manufacturer (Section D)
FRESENIUS KABI USA, LLC
50 high street
suite 50
north andover MA 01845
Manufacturer (Section G)
FRESENIUS KABI USA, LLC
50 high street
suite 50
north andover MA 01845
Manufacturer Contact
rebecca mccandless
3 corporate drive
lake zurich, IL 60047
8475502913
MDR Report Key23058353
Report Number3014732157-2025-01010
Device Sequence Number15644774
Product Code FPA
UDI-Device Identifier00811505030054
UDI-Public00811505030054
Combination Product (Y/N)N
Initial Reporter StateVA
Initial Reporter CountryUS
PMA/510(K) Number
K183311
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source User Facility
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date (Section B) 09/15/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Model NumberSET-0013-1
Device Catalogue NumberSET-0013-1
Device Lot Number3009778
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer05/07/2024
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 04/19/2024
Initial Report FDA Received Date09/15/2025
Was Device Evaluated by Manufacturer? (Y/N) Yes
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-