MAUDE Adverse Event Report: ARROW INTERNATIONAL LLC ARROW REDIGUARD IAB: 7FR 30CC; SYSTEM, BALLOON, INTRA-AORTIC

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ARROW INTERNATIONAL LLC ARROW REDIGUARD IAB: 7FR 30CC; SYSTEM, BALLOON, INTRA-AORTIC Back to Search Results
Catalog Number IAB-S730C
Medical Device Problem Code Inflation Problem (1310)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 08/20/2025
Type of Reportable Event Malfunction
Event or Problem Description
It was reported "after the catheter inserted, the balloon can not inflate completely.Change the new catheter".No patient injury or consequence reported.The patient's current condition is reported as "fine".
 
Additional Manufacturer Narrative
(b)(4).
 
Additional Manufacturer Narrative
Qn# (b)(4).The serial number on the returned sample is (b)(6).Returned for investigation was a 30cc 7fr rediguard intra-aortic balloon catheter (iabc) with the original packaging box that matches the serial number for the returned sample.The sample was returned in a cardboard box and was loosely packed within the original packaging carton.Upon return, the teflon sheath was noted on the iab catheter.The one-way valve was tethered to the short driveline tubing.The bladder was fully un-wrapped.Dried blood was noted on the exterior surfaces of the returned sample.Some dried blood was noted within the helium pathway.The customer photo was reviewed.The photo shows the iabc serial number and matches the serial number on the returned sample.The customer video was re-viewed.The video shows air being manually injected through the helium pathway; a leak was noted on the balloon.The bladder thickness was measured at six points with measurements ranging from 0.0060in-0.0070in and was within specification of process document.The one-way valve was tested and passed.A vacuum was pulled on the one-way valve, and it held for at least 1 minute according to quality system document.The catheter's central lumen was aspirated and flushed using a 60cc lab-inventory syringe.No blood or debris was noted.The iabc was leak tested in accordance with testing methods from manufacturing procedure.A leak was immediately detected from the iabc bladder membrane at approximately 21.2 to 21.5cm from the distal tip.The leak site was consistent with contact from a sharp object; no other leaks were detected.A lab inventory 0.025in guidewire was back loaded through iabc distal tip.No resistance was noted; the guidewire was able to ad-vance through the central lumen.No blood or debris was noted.A device history record (dhr) re-view was conducted for the lot number with no relevant findings.The device passed all manufacturing specifications prior to release.The reported complaint for "the balloon can not inflate completely" is confirmed.During the investi-gation, a puncture consistent with contact from a sharp object was found on the iabc bladder and this caused the reported complaint.No other leaks were detected during functional testing.Based on a review of the device history record (dhr), the product met specification upon release; however, the specifications were not met during the complaint investigation due to the bladder leak.The prob-able root cause is customer handling related.No further action is required at this time.This will be monitored for any developing trends.
 
Event or Problem Description
It was reported "after the catheter inserted, the balloon can not inflate completely.Change the new catheter".No patient injury or consequence reported.The patient's current condition is reported as "fine".
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ARROW REDIGUARD IAB: 7FR 30CC
Common Device Name
SYSTEM, BALLOON, INTRA-AORTIC
Manufacturer (Section D)
ARROW INTERNATIONAL LLC
morrisville NC
Manufacturer (Section G)
ARROW INTERNATIONAL INC.
16 elizabeth drive
chelmsford MA 01824
Manufacturer Contact
sachin sony
3015 carrington mill blvd
morrisville, NC 27560
MDR Report Key23066201
Report Number3010532612-2025-00895
Device Sequence Number13179443
Product Code DSP
UDI-Device Identifier00801902002686
UDI-Public(01)00801902002686(11)241106(17)261031(10)18F24L0001(21)
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
K981660
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,User Facility
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 08/20/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Catalogue NumberIAB-S730C
Device Lot Number18F24L0001
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 08/20/2025
Supplement Date Received by Manufacturer11/26/2025
Initial Report FDA Received Date09/16/2025
Supplement Report FDA Received Date12/27/2025
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured11/06/2024
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
N/A.; N/A.
Patient SexUnknown
-
-