| Model Number |
A209 |
| Medical Device Problem Codes |
Premature Discharge of Battery (1057); Incorrect, Inadequate or Imprecise Result or Readings (1535); Battery Problem (2885)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
08/26/2025
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
It was reported that this subcutaneous implantable cardioverter defibrillator (s-icd) emitted a battery depletion code.Moreover, this device has 4 percent remaining of battery longevity to elective replacement indicator (eri).A request was made to have data from this device analyzed.Data analysis confirmed the battery appeared to be depleting more quickly than expected.Technical services (ts) consultant recommended replacement.To date, this device remains in service.No adverse patient effects were reported.
|
| |
|
Additional Manufacturer Narrative
|
|
Revision to the initial mdr in block b5 event description and h6 impact codes.This supplemental report was created to capture additional information.
|
| |
|
Event or Problem Description
|
|
It was reported that this subcutaneous implantable cardioverter defibrillator (s-icd) emitted a battery depletion code.Moreover, this device has 4 percent remaining of battery longevity to elective replacement indicator (eri).A request was made to have data from this device analyzed.Data analysis confirmed the battery appeared to be depleting more quickly than expected.Technical services (ts) consultant recommended replacement.To date, this device remains in service.No adverse patient effects were reported.Additional information is received indicating that this device was explanted.No additional adverse patient effects were reported.
|
| |
|
Event or Problem Description
|
|
It was reported that this subcutaneous implantable cardioverter defibrillator (s-icd) emitted a battery depletion code.Moreover, this device has 4 percent remaining of battery longevity to elective replacement indicator (eri).A request was made to have data from this device analyzed.Data analysis confirmed the battery appeared to be depleting more quickly than expected.Technical services (ts) consultant recommended replacement.To date, this device remains in service.No adverse patient effects were reported.Additional information is received indicating that this device was explanted.No additional adverse patient effects were reported.
|
| |
|
Additional Manufacturer Narrative
|
|
This product has not been returned and therefore device analysis could not be performed.A review of the device history record (dhr) was performed.The review of the dhr identified that there were no process related non-conformances, scrap, or rework performed during the production that could explain the event.The reviews ensure each device meets specification prior to release for use.There is no indication the device manufacturing process contributed to the reported event.Review of labeling determined the complaint situation was listed in the manual.There was no indication in the complaint that the product was not used in accordance to labeling.The manual was unlikely to be the cause of the reported complaint; translation, wording, or graphics does not require further review.A risk review was completed and confirmed that the event of device displays error message was defined in the risk documentation.This event type has been accounted for during product risk analysis to support acceptable risk benefit for the product.Based on a thorough review of the reported complaint, boston scientific has assigned an investigation conclusion code of cause linked to device but unable to trace more specifically.
|
| |
|