| Catalog Number |
AS-IFS1 |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Code |
Air Embolism (1697)
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
The customer reported that the device, as-ifs1, airseal ifs, 120v, was being used during a robot-assisted uterine malignant tumor surgery procedure on an unknown date when it was reported, ¿during the interview, we learned that in the five most recent cases of uterine body cancer in which pan dissection was performed using a robot, subcutaneous emphysema occurred in two cases, making extubation difficult.¿ a good faith effort was completed to obtain further information; however, to date, conmed has not received a response from the reporter.There has not been any allegation of malfunction for the conmed device.This report is being raised due to the reported injury of subcutaneous emphysema.
|
| |
|
Additional Manufacturer Narrative
|
|
The device is not expected to be returned for evaluation and review.However, the complaint investigation is not complete at this time.A supplemental and final report will be filed following the completion of the complaint investigation.We will continue to monitor per regulatory requirements to help ensure patient safety.
|
| |
|
Additional Manufacturer Narrative
|
|
Neither the device nor photographic evidence was provided.Therefore, the reported event cannot be verified.The service history was reviewed, and no data was found.A device history record (dhr) review was requested from the manufacturer, and no indication of abnormalities was communicated.A two-year review of complaint history revealed there has been a total of (b)(4) complaints, regarding (b)(4) devices, for this device family and failure mode.During this same time frame (b)(4) devices have been manufactured and shipped worldwide.Should all the complaint devices have been found confirmed for this reported failure, the rate of failure would be (b)(4).Per the instructions for use, the user is advised that incorrect placement of a cannula or a trocar into subcutaneous tissue may lead to emphysema.To reduce the risk, use a low gas flow rate for the first insufflation and ensure that the insufflation instrument is correctly positioned.Long surgeries (> 200 min.), the use of many access points, duration and size of leaks at these points may also contribute to emphysema.Be sure to close leakages in trocar access points immediately.Improper placement of the insufflation instrument could cause gas penetrating a vessel or an internal organ, resulting in gas embolisms.To reduce the risk, use a low flow rate for the first insufflation and ensure that the insufflation instrument is correctly positioned.Check the position of the insufflation instrument immediately if the actual pressure rapidly reaches the nominal pressure value.Gas embolisms can also be caused by a high intra-abdominal pressure.Avoid high-pressure settings and close damaged blood vessels at once.We will continue to monitor per regulatory requirements to help ensure patient safety.
|
| |
|
Event or Problem Description
|
|
The customer reported that the device, as-ifs1, airseal ifs, 120v, was being used during a robot-assisted uterine malignant tumor surgery procedure on an unknown date when it was reported, ¿during the interview, we learned that in the five most recent cases of uterine body cancer in which pan dissection was performed using a robot, subcutaneous emphysema occurred in two cases, making extubation difficult.¿.A good faith effort was completed to obtain further information; however, to date, conmed has not received a response from the reporter.There has not been any allegation of malfunction for the conmed device.This report is being raised due to the reported injury of subcutaneous emphysema.
|
| |
|