• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: TERUMO BCT TRIMA ACCEL; TRIMA ACCEL PLATELET, PLASMA, RBC SET

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

TERUMO BCT TRIMA ACCEL; TRIMA ACCEL PLATELET, PLASMA, RBC SET Back to Search Results
Catalog Number 4824062
Medical Device Problem Codes Adverse Event Without Identified Device or Use Problem (2993); Insufficient Device Problem Information (3190)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 09/12/2025
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Investigation: the run data file (rdf) was analyzed for this event.The signals in the run data file indicate that the higher-than-expected wbc content in the platelet product was possibly the result of a wbc saturation of the lrs chamber that fell just under the detection threshold for flagging the platelet product for wbc verification, and which occurred near the end of the procedure.Additionally, based on the signals in the run data file, it cannot be ruled out that the donor's platelets may have been activating in the channel and in the lrs chamber, disrupting the packed bed and causing platelets to exit the centrifuge in an inconsistent manner.Based on the available information, it cannot be ruled out that both the lower-than-expected platelet yield and the higher-than-expected wbc content in the platelet product may have been donor-related.Investigation is in process, a follow-up report will be provided.
 
Event or Problem Description
The customer would like the run data file investigated to determine a possible cause for the elevated white blood cell (wbc) content in the platelet product.Donor unit #: (b)(6).There was not a transfusion recipient or patient involved at the time of the residual wbc testing, therefore no patient information is reasonably known at the time of the event.The platelet collection set is not available for return because it was discarded by the customer.
 
Additional Manufacturer Narrative
This report is being filed to provide additional information in d.4, h.6 and h.11.Investigation: the run data file (rdf) was analyzed for this event.The signals in the run data file indicate that the higher-than-expected wbc content in the platelet product was possibly the result of a wbc saturation of the lrs chamber that fell just under the detection threshold for flagging the platelet product for wbc verification, and which occurred near the end of the procedure.Additionally, based on the signals in the run data file, it cannot be ruled out that the donor's platelets may have been activating in the channel and in the lrs chamber, disrupting the packed bed and causing platelets to exit the centrifuge in an inconsistent manner.Based on the available information, it cannot be ruled out that both the lower-than-expected platelet yield and the higher-than-expected wbc content in the platelet product may have been donor-related.A disposable complaint history search was performed for this lot and found no other reports for similar issues on this lot.The device history records (dhr) were reviewed for this lot.There were no events noted in the dhr that would have contributed to the elevated wbc count experienced by the customer.Root cause: a root cause assessment was performed for this complaint.The signals in the run data file indicate that the higher-than-expected wbc content in the platelet product was possibly the result of a wbc saturation of the lrs chamber that fell just under the detection threshold for flagging the platelet product for wbc verification, and which occurred near the end of the procedure.Additionally, based on the signals in the run data file, it cannot be ruled out that the donor's platelets may have been activating in the channel and in the lrs chamber, disrupting the packed bed and causing platelets to exit the centrifuge in an inconsistent manner.Based on the available information, it cannot be ruled out that both the lower-than-expected platelet yield and the higher-than-expected wbc content in the platelet product may have been donor-related.
 
Event or Problem Description
The customer would like the run data file investigated to determine a possible cause for the elevated white blood cell (wbc) content in the platelet product.Donor unit #: (b)(6) there was not a transfusion recipient or patient involved at the time of the residual wbc testing, therefore no patient information is reasonably known at the time of the event.The platelet collection set is not available for return because it was discarded by the customer.
 
Event or Problem Description
The customer would like the run data file investigated to determine a possible cause for the elevated white blood cell (wbc) content in the platelet product.Donor unit #: (b)(6).There was not a transfusion recipient or patient involved at the time of the residual wbc testing; therefore, no patient information is reasonably known at the time of the event.The platelet collection set is not available for return because it was discarded by the customer.
 
Additional Manufacturer Narrative
This report is being filed to provide additional information in h.6 and h.11.Investigation: the run data file (rdf) was analyzed for this event.The signals in the run data file indicate that the higher-than-expected wbc content in the platelet product was possibly the result of a wbc saturation of the lrs chamber that fell just under the detection threshold for flagging the platelet product for wbc verification, and which occurred near the end of the procedure.Additionally, based on the signals in the run data file, it cannot be ruled out that the donor's platelets may have been activating in the channel and in the lrs chamber, disrupting the packed bed and causing platelets to exit the centrifuge in an inconsistent manner.Based on the available information, it cannot be ruled out that both the lower-than-expected platelet yield and the higher-than-expected wbc content in the platelet product may have been donor-related.A disposable complaint history search was performed for this lot and found no other reports for similar issues on this lot.The device history records (dhr) were reviewed for this lot.There were no events noted in the dhr that would have contributed to the elevated wbc count experienced by the customer.Investigation is in process, a follow-up report will be provided.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TRIMA ACCEL
Common Device Name
TRIMA ACCEL PLATELET, PLASMA, RBC SET
Manufacturer (Section D)
TERUMO BCT
lakewood CO 80215
Manufacturer (Section G)
TERUMO BCT
10810 w. collins ave
lakewood CO 80215
Manufacturer Contact
scot hilden
10810 w. collins ave
lakewood, CO 80215
MDR Report Key23235762
Report Number1722028-2025-00224
Device Sequence Number21050895
Product Code GKT
UDI-Device Identifier05020583824065
UDI-Public05020583824065
Combination Product (Y/N)N
Initial Reporter StateRI
Initial Reporter CountryUS
PMA/510(K) Number
BK190332
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Health Professional
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup,Followup
Report Date (Section B) 10/07/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue Number4824062
Device Lot Number2506026242
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 09/13/2025
Supplement Date Received by Manufacturer11/10/2025
12/04/2025
Initial Report FDA Received Date10/07/2025
Supplement Report FDA Received Date11/20/2025
12/10/2025
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured06/02/2025
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient SexUnknown
-
-