| Model Number |
N/A |
| Medical Device Problem Code |
Fluid/Blood Leak (1250)
|
| Health Effect - Clinical Codes |
Distress (2329); Insufficient Information (4580)
|
| Date of Event |
05/29/2025
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
H11: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.The manufacturer has received the sample and will be evaluated.A supplemental will be submitted with evaluation results.
|
| |
|
Event or Problem Description
|
|
It was reported by customer that tubing cracked at distal end next to connection of male luer lock.
|
| |
|
Event or Problem Description
|
|
Additional information received on 22oct2025: there was no patient injury, but delay in care and trauma to child for being re accessed with a new needle so medication could be re-started.
|
| |
|
Additional Manufacturer Narrative
|
|
H11: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.The complaint of a leak is confirmed; however, the exact cause could not be determined.One 20ga powerloc max infusion set was returned for evaluation.An initial visual observation revealed some biological residue on the sample.The safety mechanism was observed to be engaged and a needleless injection cap was present.A functional test of flushing the infusion set with water using a 12 ml syringe was performed.A leak was observed in the tubing just distal to the luer hub.Microscopic inspection of the fracture surfaces exhibited striated patterns and radiating tear marks.The investigation findings are indicative of flexural fatigue-based failures, which may have been a contributing factor to the extension tubing damage.Repetitive mechanical stresses such as twisting and kinking may have contributed to the observed event; however, it appeared that additional unidentified factors may have contributed.The device is a supplied component and the supplier has been notified of this event.This complaint will be recorded for future trending and monitoring purposes.
|
| |
|