SYNTHES GMBH SCHANZSCR Ø5 L200/50 SST; APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION
|
Back to Search Results |
|
| Catalog Number |
294.560 |
| Medical Device Problem Codes |
Break (1069); Device-Device Incompatibility (2919)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
09/25/2025
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Product complaint # (b)(4) this report is being submitted pursuant to the provisions of 21 cfr, part 803 (and/or part 4, as applicable).This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by depuy synthes, or its employees that the report constitutes an admission that the product, depuy synthes, or its employees caused or contributed to the potential event described in this report.Additional narrative: if information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|
Event or Problem Description
|
|
It was reported during removing the patient's external tutor for a cem femur intramedullary nail, the doctor realized that two schanz were broken and could not remove them from the patient.No patient consequences.
|
| |
|
Additional Manufacturer Narrative
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.H11 additional narrative: added: h4.H6: the product was not returned to j&j medtech orthopaedics; however, photos were provided for review.The photo investigation revealed tip of the schanz screw is broken, remnant is not observed on the evidence provided, distal area of the threaded body close to the tip is bent, based on the photo evidence we cannot observe if disassembly is possible or not, however, the bent condition can affect the assembly or disassembly of the devices.Stated on the large and medium external fixators surgical technique guide, se_808402 rev.Ab, the following is advised: precautions: the tip of the schanz screw should be embedded in the far cortex to effectively resist cantilever forces and to provide sufficient stability.Only when bones are osteoporotic, the schanz screw has to be screwed a bit further into the distant cortical bone, and it may even slightly penetrate through it since this can increase anchoring stability the observed condition is consistent with a torsional failure which is likely due to the application of significant torque during the implantation process.As the device was not returned, an as-received condition could not be assessed, and a dimensional inspection and document/specification review were not completed.The overall complaint was confirmed as the observed condition of the schanzscr ø5 l200/50 sst would have contributed to the complained device issue.Based on the investigation findings, it has been determined that no corrective and/or preventative action is proposed.There is no indication that a design or manufacturing issue has caused the reported complaint condition.As part of j&j medtech orthopaedics quality process, all devices are manufactured, inspected, and released to approved specifications.Additional monitoring for any potential safety signals will be conducted through complaint trending and other post-market safety surveillance activities.Device history lot: 0/24/2025: dhr review for this following part/lot combination conducted: product code: 294.560-15.Lot number: 48963p6.Manufacturing date: 01/14/2025.Expiry date: n/a (non-sterile part).No non-conformance / manufacturing irregularities were identified.(b)(6).A dhr evaluation was performed for the finished device lot: 48963p6, article: 294.560-15, and no non-conformances / manufacturing irregularities were identified.Device history review: the device lot number is unknown; therefore, a device history review could not be performed.If the lot/serial number becomes available, the record will be re-assessed.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|
Additional Manufacturer Narrative
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.H11 additional narrative: h3, h6: the product was returned to j&j medtech orthopaedics for evaluation.Visual inspection of the returned device found threaded tip of the device is broken, remnant was not returned for revision.Shaft on the distal affected area is bent.Based on the observed damage, assembly and disassembly between mating devices is compromised.The observed condition of the device was consistent with a random component failure that may have been caused by exposure to unintended forces.A dimensional inspection was unable to be performed due to the post-manufacturing damage.A functional test was not performed since it was not applicable to the complaint condition.The overall complaint was confirmed as the observed condition of the schanzscr ø5 l200/50 sst would have contributed to the complained device issue.Based on the investigation findings, it has been determined that no corrective and/or preventative action is proposed.There is no indication that a design or manufacturing issue has caused the reported complaint condition.As part of depuy synthes quality process, all devices are manufactured, inspected, and released to approved specifications.Additional monitoring for any potential safety signals will be conducted through complaint trending and other post-market safety surveillance activities.Device history lot: dhr review for this following part/lot combination conducted: product code: 294.560-15 lot number: 48963p6 manufacturing date: 01/14/2025.Expiry date: n/a (non-sterile part).No non-conformance / manufacturing irregularities were identified a dhr evaluation was performed for the finished device lot: 48963p6, article: 294.560-15, and no non-conformances / manufacturing irregularities were identified.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|