Catalog Number 64956040
Medical Device Problem Code Unstable (1667)
Health Effect - Clinical Code Joint Laxity (4526)
Date of Event 09/17/2025
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported by the customer that "small gmrs femoral component experienced polyethylene wear failure of the bumper axle bushings.Some wear was observed on the small gmrs femoral component and the small gmrs rotating component.Fretting corrosion was observed on the trunnion and taper of the 40mm gmrs extension piece linking the small gmrs proximal tibia and kotz to gmrs adaptor.The extension piece was easy to remove from the adaptor but extremely difficult to remove from the proximal tibia.Blackened flakes observed at tibial trunions." patient presented with instability of the knee 15 years after the components were implanted.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
GMRS EXTENSION PIECE 40MM
Common Device Name
PROSTHESIS, KNEE, FEMOROTIBIAL, CONSTRAINED, CEMENTED, METAL/POLYMER
Manufacturer (Section D)
STRYKER ORTHOPAEDICS-MAHWAH
325 corporate drive
mahwah NJ 07430
Manufacturer (Section G)
STRYKER ORTHOPAEDICS-LIMERICK
raheen business park
limerick NA
EI   NA
Manufacturer Contact
brad curtis
325 corporate drive
mahwah, NJ 07430
2018315000
MDR Report Key23334676
Report Number0002249697-2025-01133
Device Sequence Number10612508
Product Code KRO
UDI-Device Identifier07613327049169
UDI-Public07613327049169
Combination Product (Y/N)N
Initial Reporter CountryCA
PMA/510(K) Number
K023087
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Company Representative
Initial Reporter Occupation Other
Type of Report Initial
Report Date (Section B) 10/20/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Catalogue Number64956040
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? No
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 09/22/2025
Initial Report FDA Received Date10/20/2025
Was Device Evaluated by Manufacturer? (Y/N) No
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention; Hospitalization;
Patient Age52 YR
Patient SexMale
-
-