Vascular occlusion [vascular skin disorder], rha 2 mepi in the lips [off label use].Case narrative: on 02-oct-2025, primevigilance notified teoxane geneva of several adverse events.A same reporter reported having epxrienced with her staff, 3 vascular occlusions in a week using rha2 mepi.However, only 2 patients could be identified on the information provided.For this reason, 2 complaints were opened (rc/2510014 and rc/2510015) considering a possible typo.The current complaint has been opened for the second patient.The later had been injected during the week of (b)(6) 2025 with rha 2 mepi and experienced a vascular occlusion in the lips (current complaint).Despite several reminders, no further information could be retrieved.The complaint was considered closed.Case comments: ¿ alam, m., kakar, r., dover, j., harikumar, v., kang, b., wan, h., poon, e.And jones, d., 2021.Rates of vascular occlusion associated with using needles vs cannulas for filler injection.Jama dermatology, 157(2), p.174.Cassiano, d., miyuki iida, t., lúcia recio, a.And yarak, s., 2020.Delayed skin necrosis following hyaluronic acid filler injection: a case report.Journal of cosmetic dermatology, 19(3), pp.582-584.Fakih-gomez, n., orte-aldea, m., poonja, k.And khanna, d., 2019.Hyaluronic acid filler emergency kit.The american journal of cosmetic surgery, 36(4), pp.183-190.Hirsch, p., infanger, m.And kraus, a., 2020.A case of upper lip necrosis after cosmetic injection of hyaluronic acid soft-tissue filler¿does capillary infarction play a role in the development of vascular compromise, and what are the implications? journal of cosmetic dermatology, 19(6), pp.1316-1320.Lima, v., regattieri, n., pompeu, m.And costa, i., 2019.External vascular compression by hyaluronic acid filler documented with high-frequency ultrasound.Journal of cosmetic dermatology, 18(6), pp.1629-1631.Loh, k., phoon, y., phua, v.And kapoor, k., 2018.Successfully managing impending skin necrosis following hyaluronic acid filler injection, using high-dose pulsed hyaluronidase.Plastic and reconstructive surgery - global open, 6(2), p.E1639.Loyal, j., hartman, n., fabi, s., butterwick, k.And goldman, m., 2022.Cutaneous vascular compromise and resolution of skin barrier breakdown after dermal filler occlusion¿implementation of evidence-based recommendations into real-world clinical practice.Dermatologic surgery, 48(6), pp.659-663.Ors, s., 2020.The effect of hyaluronidase on depth of necrosis in hyaluronic acid filling-related skin complications.Aesthetic plastic surgery, 44(5), pp.1778-1785.Ortiz, a., ahluwalia, j., song, s.And avram, m., 2020.Analysis of u.S.Food and drug administration data on soft-tissue filler complications.Dermatologic surgery, 46(7), pp.958-961.Sito g, manzoni v, sommariva r.Vascular complications after facial filler injection: a literature review and meta-analysis.J clin aesthet dermatol.2019 jun;12(6):e65-e72 snozzi, p.And van loghem, j., 2018.Complication management following rejuvenation procedures with hyaluronic acid fillers¿an algorithm-based approach.Plastic and reconstructive surgery - global open, 6(12), p.E2061.Soares, d., 2022.Bridging a century-old problem: the pathophysiology and molecular mechanisms of ha filler-induced vascular occlusion (fivo)¿implications for therapeutic interventions.Molecules, 27(17), p.5398.Worley, n., lupo, m., holcomb, k., kullman, g., elahi, e.And elison, j., 2020.Hyperbaric oxygen treatment of keratitis following facial hyaluronic acid injection.Ochsner journal, 20(2), pp.193-196.
|