• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BOLTON MEDICAL, INC. RELAY PRO NBS THORACIC STENT-GRAFT SYSTEM; STENT, ENDOVASCULAR GRAFT, AORTIC

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BOLTON MEDICAL, INC. RELAY PRO NBS THORACIC STENT-GRAFT SYSTEM; STENT, ENDOVASCULAR GRAFT, AORTIC Back to Search Results
Catalog Number 28-N4-40-204-40U
Medical Device Problem Codes Adverse Event Without Identified Device or Use Problem (2993); Insufficient Device Problem Information (3190)
Health Effect - Clinical Codes Vascular Dissection (3160); Insufficient Information (4580)
Date of Event 11/20/2024
Type of Reportable Event Death
Additional Manufacturer Narrative
Bolton medical, inc.(d/b/a terumo aortic), herein known as the "company", is submitting this report pursuant to 21 cfr part 803, has made reasonable efforts to obtain complete information, and has provided as much as is available to the company as of the submission date of this report.This report is based on information obtained by the company, which may not have been able to fully investigate or verify prior to the date the report was required by the regulations.Any required fields that are unpopulated are blank because the information is currently unknown, unavailable, or not applicable.This report does not constitute an admission or a conclusion by anyone that the device caused or contributed to the event described in the report.In particular, this report does not constitute a legal admission by anyone that the product described in this report has any defects or has malfunctioned, as defined from a legal standpoint.These words are included in the report and are fixed items for selection created by the certain regulations, to categorize the type of event solely for the purpose of reporting pursuant to part 803.This statement should be included with any information or report disclosed to the public under the freedom of information act.
 
Event or Problem Description
"subject presented a chronic aortic dissection, debakey type iii stanford type b.One relay pro nbs was used during index procedure.Site received an alert through their epic system that the patient is deceased as of (b)(6) 2024, but there is no documentation.There is no further information in the patient's chart, outside facilities, or obituary.Site has tried contacting the pcp on file, but they do not have any record of the patient.Their emergency contact number is out of service." patient outcome: "deceased".
 
Additional Manufacturer Narrative
All relevant device history records (dhrs) for the relay pro nbs (n4) thoracic stent-graft system (28-n4-40-204-40u) with final assembly lot# 2304060135, including final assembly (labeling), stent-graft system/packaging, delivery system assembly and stent-graft assembly, were inspected and no discrepancies were found.No discrepancies were noted in the qc inspections performed within the corresponding sub-assembly and final assembly processes.Sterilization records show the device received the required sterilization dose on (b)(6) 2023.There were no nonconformances or reworks in relation to the device.Review of the device history records showed no issues were found during the manufacture of the devices.The pre-case plan and intra-operative ct imaging were not available for evaluation.The patient underwent a tevar procedure to treat a chronic type b aortic dissection on (b)(6) 2023 with a relay pro nbs device (28-n4-40-204-40u).No issues were reported regarding the use of the delivery system or the implanted device.Without a pre-case plan and ct study, the anatomy evaluation, aortic sizing, graft selection and stent-graft positioning cannot be confirmed.In conclusion, a review of the device history records showed no issues with the manufacture of the devices.The root cause of the reported failure of other adverse event post-procedure resulting in death could not be determined.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
RELAY PRO NBS THORACIC STENT-GRAFT SYSTEM
Common Device Name
STENT, ENDOVASCULAR GRAFT, AORTIC
Manufacturer (Section D)
BOLTON MEDICAL, INC.
799 international parkway
sunrise FL 33325
Manufacturer Contact
manuel benitez
799 international parkway
sunrise, FL 33325
9548389699
MDR Report Key23441247
Report Number2247858-2025-00252
Device Sequence Number8552289
Product Code MIH
UDI-Device Identifier00843576150768
UDI-Public00843576150768
Combination Product (Y/N)N
Initial Reporter CountryUS
PMA/510(K) Number
P200045
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2023
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Company Representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 03/24/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Expiration Date07/01/2025
Device Catalogue Number28-N4-40-204-40U
Device Lot Number2304060135
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 10/06/2025
Supplement Date Received by Manufacturer02/27/2026
Initial Report FDA Received Date10/31/2025
Supplement Report FDA Received Date03/24/2026
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured07/02/2023
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Death;
Patient Age83 YR
Patient SexMale
-
-