Model Number TCDS0301-XT
Medical Device Problem Codes Incomplete Coaptation (2507); Device Damaged by Another Device (2915)
Health Effect - Clinical Codes Mitral Valve Insufficiency/ Regurgitation (4451); Tricuspid Valve Insufficiency/ Regurgitation (4453)
Date of Event 10/07/2025
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported on (b)(6) 2025 that the patient presented with grade 5 functional tricuspid regurgitation (tr) for a triclip procedure.During the procedure, 2 triclips were implanted successfully.The tr was reduced to grade 1 post procedure.On (b)(6) 2025, first triclip was observed to have single leaflet device attachment(slda) from septal leaflet.Due to the movement of first triclip, second triclip also had slda from septal leaflet.The patient returned with recurrent tr of grade 3.There was no clinically significant delay.
 
Additional Manufacturer Narrative
The device remains implanted in patient.The device will not be returned for evaluation.Investigation is not yet complete.A follow-up report will be submitted with all additional relevant information.
 
Additional Manufacturer Narrative
The device was not returned for analysis.A review of the lot history record revealed no manufacturing nonconformities issued to the reported lot that would have contributed to this event.Additionally, a review of the complaint history identified no similar complaints reported from this lot.The investigation was unable to determine the cause for the reported device damaged by another device (caused damage).The reported single leaflet device attachment (slda) resulting in tricuspid valve regurgitation appears to have been a cascading effect of the device being damaged by another device.Tricuspid valve regurgitation is a known possible complication associated with triclip procedures.The reported serious injury/illness/impairment was the result of case-specific circumstances.There is no indication of a product issue with respect to manufacture, design or labeling.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TRICLIP G4 SYSTEM
Common Device Name
TRICUSPID VALVE REPAIR DEVICE, PERCUTANEOUSLY DELIVERED
Manufacturer (Section D)
ABBOTT MEDICAL
5050 nathan lane n
plymouth MN 55442
Manufacturer (Section G)
ABBOTT VASCULAR, REG # 3005070406
3885 bohannon drive
menlo park CA 94025
Manufacturer Contact
karen krouse
5050 nathan lane n
plymouth, MN 55442
6517565400
MDR Report Key23442107
Report Number2135147-2025-06307
Device Sequence Number14648228
Product Code NPS
UDI-Device Identifier05415067047731
UDI-Public(01)05415067047731(17)260211(10)50211R3049
Combination Product (Y/N)N
Initial Reporter StateWA
Initial Reporter CountryUS
PMA/510(K) Number
P230007
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2025
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 01/21/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date02/11/2026
Device Model NumberTCDS0301-XT
Device Catalogue NumberTCDS0301-XT
Device Lot Number50211R3049
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 10/07/2025
Supplement Date Received by Manufacturer01/12/2026
Initial Report FDA Received Date10/31/2025
Supplement Report FDA Received Date01/21/2026
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured02/12/2025
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient SexUnknown
-
-