Model Number ARTHREX ANGEL PRP KIT (US TRAY)
Medical Device Problem Code Device Emits Odor (1425)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 10/24/2025
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Investigation is in process.A follow-up report will be provided upon availability of additional information.
 
Event or Problem Description
On 10/24/2025, it was reported by a sales representative via (b)(4) that an abs-10061t arthrex angel prp kit experienced a malfunction.The blood was not pulled up during the spin cycle at all.There was also a burning smell coming from the outlet where the machine was plugged in.This was discovered during the case with no patient harm.
 
Additional Manufacturer Narrative
Additional information: g3, h3, h6.Based on the information provided which may include the device (if available and returned), pictures, videos, event description, and any additional information from the field, arthrex was able to conclude a most likely cause.The most likely cause of the reported failure of the angel prp kit, is the external power source where the machine was plugged in.The failure may have resulted from a defective or compromised electrical outlet rather than a device-related malfunction.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ARTHREX ANGEL PRP KIT (US TRAY)
Common Device Name
PLATELET AND PLASMA SEPARATOR
Manufacturer (Section D)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer (Section G)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer Contact
jared engle
8009337001
MDR Report Key23465206
Report Number1220246-2025-04984
Device Sequence Number13284175
Product Code ORG
UDI-Device Identifier00888867279919
UDI-Public(01)00888867279919(11)240201(17)270131(10)4339155000
Combination Product (Y/N)N
Initial Reporter StateKS
Initial Reporter CountryUS
PMA/510(K) Number
BK180180
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Distributor
Initial Reporter Occupation Administrator/Supervisor
Type of Report Initial,Followup
Report Date (Section B) 03/20/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberARTHREX ANGEL PRP KIT (US TRAY)
Device Catalogue NumberABS-10061T
Device Lot Number4339155000
Was Device Available for Evaluation? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 10/24/2025
Supplement Date Received by Manufacturer03/20/2026
Initial Report FDA Received Date11/04/2025
Supplement Report FDA Received Date03/20/2026
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured02/01/2024
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-