ABBOTT IRELAND DIAGNOSTICS DIVISION ARCHITECT TOTAL B-HCG; SYSTEM, TEST, HUMAN CHORIONIC GONADOTROPIN Back to Search Results
Catalog Number 07K78-25
Medical Device Problem Code False Positive Result (1227)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 01/01/2022
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
An evaluation is in process.A follow up report will be submitted when the evaluation is complete.All available patient information was included.Additional patient details are not available.
 
Event or Problem Description
An article by jaroslav racek, ivana potocová, daniel rajdl, ladislav trefil, marie ¿olcová.¿false positive result of human chorionic gonadotropin caused by human anti-mouse antibodies¿, biochem med (zagreb) 2023;33(1):010802.The study noted false positive architect total b-hcg results (1450 u/l) on a 45-year-old woman the patient was sent to a regional hospital with the diagnosis of pregnancy of unknown localization, to exclude ectopic pregnancy.Here, due to a slight decrease in hcg concentration, she underwent a revision of her uterine cavity with a negative finding.As there was another slight decrease in the hcg concentration the next day, the uterine cavity revision was repeated and supplemented with a laparoscopic examination where the gestational sac could not be found.The patient was then transferred to a university hospital where methotrexate administration was considered.However, blood was first drawn for hcg determination: < 1 u/l (reagent kit elecsys hcg+¿b, based on electrochemiluminescence (eclia), cobas e602 analyzer (roche diagnostics) in two different samples.One of the above-mentioned samples was then sent to two other laboratories to obtain results using kits from other manufacturers.The results were 2265 u/l on an abbott architect i1000sr and 4.2 u/l using reagent kit access total beta-hcg, based on chemiluminescence (clia) on unicel dxi 800 access immunoassay system (beckman coulter).Therefore, the presence of heterophilic anti-mouse antibodies was suspected.After incubation of the sample in heterophilic blocking tubes, the hcg result was < 1.2 u/l on an abbott architect i1000sr.Therefore, pregnancy was ruled out, and the patient was discharged to home care.No additional impact to patient management was reported.
 
Additional Manufacturer Narrative
Data and information provided by the customer were reviewed and support the complaint issue.Manufacturing documentation for the likely cause lot did not identify any issues associated with the complaint issue.The ticket search determined that there is no increase in complaint activity for this list number.Labelling was reviewed and found to adequately address the issue under review.Interference by heterophilic antibodies was confirmed.According to the package insert heterophilic antibodies in human serum can react with reagent immunoglobulins, interfering with in vitro immunoassays.The presence of heterophilic antibodies in a patient specimen may demonstrate anomalous values.Based on the investigation no systemic issue or product deficiency was identified and the product is performing as expected.
 
Event or Problem Description
An article by jaroslav racek, ivana potocová, daniel rajdl, ladislav trefil, marie ¿olcová.¿false positive result of human chorionic gonadotropin caused by human anti-mouse antibodies¿, biochem med (zagreb) 2023;33(1):010802.The study noted false positive architect total b-hcg results (1450 u/l) on a 45-year-old woman the patient was sent to a regional hospital with the diagnosis of pregnancy of unknown localization, to exclude ectopic pregnancy.Here, due to a slight decrease in hcg concentration, she underwent a revision of her uterine cavity with a negative finding.As there was another slight decrease in the hcg concentration the next day, the uterine cavity revision was repeated and supplemented with a laparoscopic examination where the gestational sac could not be found.The patient was then transferred to a university hospital where methotrexate administration was considered.However, blood was first drawn for hcg determination: < 1 u/l (reagent kit elecsys hcg+b, based on electrochemiluminescence (eclia), cobas e602 analyzer (roche diagnostics) in two different samples.One of the above-mentioned samples was then sent to two other laboratories to obtain results using kits from other manufacturers.The results were 2265 u/l on an abbott architect i1000sr and 4.2 u/l using reagent kit access total beta-hcg, based on chemiluminescence (clia) on unicel dxi 800 access immunoassay system (beckman coulter).Therefore, the presence of heterophilic anti-mouse antibodies was suspected.After incubation of the sample in heterophilic blocking tubes, the hcg result was < 1.2 u/l on an abbott architect i1000sr.Therefore, pregnancy was ruled out, and the patient was discharged to home care.No additional impact to patient management was reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ARCHITECT TOTAL B-HCG
Common Device Name
SYSTEM, TEST, HUMAN CHORIONIC GONADOTROPIN
Manufacturer (Section D)
ABBOTT IRELAND DIAGNOSTICS DIVISION
lisnamuck
co. longford
longford N39E9 32
EI  N39E932
Manufacturer (Section G)
ABBOTT IRELAND DIAGNOSTICS DIVISION
lisnamuck
co. longford
longford N39E9 32
EI   N39E932
Manufacturer Contact
nicole jenne
max-planck-ring 2
post market surveillance
wiesbaden 65205
GM   65205
6122582960
MDR Report Key23474580
Report Number3005094123-2025-00556
Device Sequence Number10195760
Product Code DHA
UDI-Device Identifier00380740014964
UDI-Public(01)00380740014964
Combination Product (Y/N)N
Initial Reporter CountryEZ
PMA/510(K) Number
K983424
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Foreign,Literature,Health Professional
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 11/25/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Catalogue Number07K78-25
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 10/21/2025
Supplement Date Received by Manufacturer11/25/2025
Initial Report FDA Received Date11/05/2025
Supplement Report FDA Received Date11/25/2025
Was Device Evaluated by Manufacturer? (Y/N) Yes
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
ARC I1000SR MOD,01L86-01, SN# UNKNOWN; ARC I1000SR MOD,01L86-01, SN# UNKNOWN
Outcome Attributed to Adverse Event Other;
Patient Age45 YR
Patient SexFemale
-
-