Model Number 102096-81A
Medical Device Problem Code Premature End-of-Life Indicator (1480)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 10/09/2025
Type of Reportable Event Malfunction
Event or Problem Description
Senseonics was made aware of an incident where user received an early sensor replacement alert resulting in an early sensor removal.
 
Additional Manufacturer Narrative
The manufacturer is currently performing an investigation and will provide the results with the supplemental report.
 
Additional Manufacturer Narrative
D2b.Corrected from sba to qhj.
 
Additional Manufacturer Narrative
The sensor replacement alert was first presented to the user on 9 oct 2025, day 160 after insertion.The sensor was tested in-house, and the review of investigation analysis revealed a loss of chemical performance.The system correctly disabled the sensor when it detected the performance failure, and the system's self-test functions were working normally.The root cause of the performance failure was due to the oxidation of the glucose indicating chemistry in the sensor hydrogel.The user was provided with a replacement sensor as part of the resolution.B4.Date of this report 08 jan 2026.G3.Date received by the manufacturer? 08 jan 2026.H3.Device evaluated by manufacturer?yes.H6.Type of investigation updated to 10.H6.Investigation findings updated to 3231.H6.Investigation conclusions updated to 4307.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
EVERSENSE SENSOR
Common Device Name
IMPLANTABLE GLUCOSE MONITORING SYSTEM, SENSOR
Manufacturer (Section D)
SENSEONICS INC.
20451 seneca meadows parkway
germantown MD 20876 7005
Manufacturer (Section G)
SENSEONICS INC.
20451 seneca meadows parkway
germantown MD 20876 7005
Manufacturer Contact
vallikannu somasundaram
20451 seneca meadows parkway
germantown, MD 20876-7005
MDR Report Key23507468
Report Number3009862700-2025-01799
Device Sequence Number9048173
Product Code QHJ
UDI-Device Identifier00817491022950
UDI-Public00817491022950
Combination Product (Y/N)Y
Initial Reporter CountryUS
PMA/510(K) Number
P160048
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2025
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Consumer
Initial Reporter Occupation Other
Type of Report Initial,Followup,Followup
Report Date (Section B) 01/15/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Lay User/Patient
Device Expiration Date06/28/2025
Device Model Number102096-81A
Device Catalogue NumberFG-7200-00-301
Device Lot Number01E284S
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer11/03/2025
Is the Reporter a Health Professional? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 10/10/2025
Supplement Date Received by Manufacturer01/08/2026
01/15/2026
Initial Report FDA Received Date11/09/2025
Supplement Report FDA Received Date01/08/2026
01/15/2026
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured07/11/2024
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient Age64 YR
Patient SexMale
-
-