| Model Number |
MA60AC |
| Medical Device Problem Code |
Material Twisted/Bent (2981)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
10/14/2025
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
A product was not returned for analysis.Complaint history and product history records were reviewed and documentation indicated the product met release criteria.Root cause has not been identified.The manufacturer internal reference number is: (b)(4).
|
| |
|
Event or Problem Description
|
|
A non-healthcare professional reported that during an intraocular lens (iol) implantation procedure, the lead haptic was improperly folded.The procedure was completed on the same day without any contact or harm to the patient.Additional information has been requested.
|
| |
|
Additional Manufacturer Narrative
|
|
The product was not returned.A device history record review and a non-conformance review of the reported lot number was conducted.The deviation review did not reveal any potential contributing factors to the reported complaint and all corresponding production release specifications defined in the device master record were met.The account indicated the use of an unspecified company cartridge.It is unknown if qualified products were used.The company model is only qualified for use in the company cartridges.A handpiece and viscoelastic were indicated which are not qualified for use with this lens, with any of the qualified lens/cartridge combinations.The root cause is most likely related to a failure to follow the (instructions for use) ifu.A handpiece and viscoelastic were indicated which are not qualified for use with this lens, with any of the qualified lens/cartridge combinations.Company foldable iols are qualified for use with an company qualified delivery system (handpiece and cartridge) and ophthalmic viscosurgical device (ovd) combination.The use of an unqualified combination may cause damage to the iol and potential complications during the implantation process.The manufacturer internal reference number is: (b)(4).
|
| |
|
Additional Manufacturer Narrative
|
|
Additional information provided in d.9., h.3., h.6.And h.11.The lens was returned positioned incorrectly (posterior surface up) in the lens case inside the lens carton.Solution was dried on the lens.One haptic was bent severely at the gusset area at the exit of the haptic insertion area of the optic.The optic was semi-folded and torn from the edge to the optic center.Another area of the optic anterior edge was split.A device history record review and a non-conformance review of the reported lot number was conducted.The deviation review did not reveal any potential contributing factors to the reported complaint and all corresponding production release specifications defined in the device master record were met.The account indicated the use of an unspecified monarch cartridge.It is unknown if qualified products were used.The company model is only qualified for use in the company and cartridges.A handpiece and viscoelastic were indicated which are not qualified for use with this lens, with any of the qualified lens/cartridge combinations.One haptic was severely bent/misfolded.This was most likely interpreted as the reported complaint.The root cause is most likely related to a failure to follow the (instructions for use) ifu.A handpiece and viscoelastic were indicated which are not qualified for use with this lens, with any of the qualified lens/cartridge combinations.The ifu instructs: company foldable iols are qualified for use with an company qualified delivery system (handpiece and cartridge) and ophthalmic viscosurgical device (ovd) combination.The ifu instructs that an company qualified delivery system and viscoelastic combination should be used.The use of an unqualified combination may cause damage to the lens and potential complications during the implantation process.The ifu instructs: use holding forceps to grasp the lens by the optic edge and gently place the lens anterior side up into the back of the ovd-filled cartridge.The lens should be inserted until it is centered with or slightly past the outline etched into the top of the cartridge.Lenses with a 6.5 mm optic diameter may need to be pre-folded for easy entry into the back of the cartridge.Lens may be pre-folded by gently applying pressure to the edge of the lens while holding the central optic with forceps.The trailing haptic will extend from the proximal end of the cartridge.Position the trailing haptic to the left of the haptic post as shown in the detailed view.This will allow the plunger to go past the haptic during the initial advancement of the plunger into the cartridge.Verify the lens is positioned on the bottom surface of the cartridge.The haptic should be maintained to the left of the post when the lens is loaded correctly.Accurate positioning of the lens will decrease the potential for optic and haptic damage.The manufacturer internal reference number is: (b)(4).
|
| |
|