Model Number AU681-10E CHEMISTRY ANALYZER
Medical Device Problem Code Low Test Results (2458)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 10/17/2025
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Beckman coulter field service engineer (fse) confirmed that the probable cause was identified as malfunctioning solenoid valves.The fse replaced the solenoid valve to resolve the reported issue.Section a2, a4 and a5: information not provided by the customer.The beckman coulter internal identifier is (b)(4).
 
Event or Problem Description
The customer reported recovering low glucose (glu) and ion selective electrode (ise) results, which included sodium (na) when run on their au680 chemistry analyzer (pn b96696, sn (b)(6)).There was no report of change to treatment, injury or death associated with this event.The customer did not provide patient data or patient demographics.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
AU681-10E CHEMISTRY ANALYZER
Common Device Name
ANALYZER, CHEMISTRY (PHOTOMETRIC, DISCRETE), FOR CLINICAL USE
Manufacturer (Section D)
BECKMAN COULTER INC.
250 s. kraemer blvd.
brea CA 92821
Manufacturer (Section G)
BECKMAN COULTER MISHIMA K. K.
454-32 higashino
nagaizumi-cho sunto-gun
shizuoka JP-NO TA 4
JA   JP-NOTA 41
Manufacturer Contact
shama agtey
1000 lake hazeltine drive
chaska, MN 55318
9524916938
MDR Report Key23533960
Report Number9612296-2025-00987
Device Sequence Number13017105
Product Code JJE
UDI-Device Identifier14987666543009
UDI-Public(01)14987666543009(11)170712
Combination Product (Y/N)N
Initial Reporter StateAL
Initial Reporter CountryUS
PMA/510(K) Number
K961274
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional,User Facility
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date (Section B) 11/12/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberAU681-10E CHEMISTRY ANALYZER
Device Catalogue NumberC63520
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 10/17/2025
Initial Report FDA Received Date11/12/2025
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured07/12/2017
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
Yes
Usage of Device Unknown
Patient Sequence Number1
Patient SexUnknown
-
-