Subject id: (b)(6).Study no: (b)(6).Clinical adverse event received for revision ¿ infection, device and procedure (relatedness), device related: no information provided, procedure related: no information provided, date of event: 17 oct 2025, date of implant: on (b)(6) 2025, date of revision: on (b)(6) 2025, device location: left.Treatment/impact: components removed (stem, head, liner, shell).Depuy synthes products used: catalog number: 121722058, lot number: m9551x, component type: shell, description: pinnacle shell sector 58mm.Catalog number: 136540730m lot number: 4549269m component type: headm description: biolox delta revision head 12/14 40mm +8.5, catalog number: 101012070m lot number: 4724370m component type: stemm description: actis collared high offset femoral stem sz 7, catalog number: 122140058, lot number: m9976f, component type: liner, description: pinnacle altrx 58mm x 40mm neutral.Catalog number: 121730500, lot number: pu236738, component type: screw, description: cancellous bone screw 30mm.
|
|
Product complaint#: (b)(4).This report is being submitted pursuant to the provisions of 21 cfr, part 803 (and/or part 4, as applicable).This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by depuy synthes, or its employees that the report constitutes an admission that the product, depuy synthes, or its employees caused or contributed to the potential event described in this report.Additional narrative: d4: udi: the expiration date is currently not available.Therefore, the full udi is currently not available.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
|
Product complaint # (b)(4).Investigation summary: no device associated with this report was received for examination.The product investigation found no evidence suspecting an error in the manufacturing or material that would be a contributing factor in the reported allegation(s).A records evaluation (mre) was not perform.As part of our company quality system process, all devices are manufactured, inspected, and distributed to approved specifications.Additional complaint information monitoring for potential safety signals will be conducted through complaint trending as part of the post-market surveillance.If additional information is made available, the investigation will be updated as applicable.Device history lot: the product investigation found no evidence suspecting an error in the manufacturing or material that would be a contributing factor in the reported allegation(s).A manufacturing records evaluation (mre) was not performed.H11 additional narrative: added: d4 (exp.Date) corrected: d4 (primary udi number).Patient details: (b)(6).
|