|
AVANOS MEDICAL INC. INTRODUCER KIT FOR GASTROSTOMY FEEDING TUBE, 20FR DILATOR; DH EF PERC PLACEMENT PRODUCTS
|
Back to Search Results |
|
| Model Number |
98432 |
| Medical Device Problem Code |
Break (1069)
|
| Health Effect - Clinical Codes |
Abscess (1690); Bacterial Infection (1735)
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
The actual complaint product was not returned for evaluation.The device history record for the reported lot number, 30349612, in this complaint was reviewed and the material was produced according to the manufacturing procedures and met the quality requirements.All information reasonably known as of 11-nov-2025 has been included in this health authority report.Should additional information be obtained, a follow-up health authority report will be provided.The information provided by avanos medical, inc.Represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to avanos medical, inc.Avanos medical, inc.Has no independent knowledge of the event reported but is relaying the information that was provided by the user facility where the incident occurred.This product incident is documented in the avanos medical, inc.Complaint database and identified as complaint (b)(4).This information is submitted pursuant to 21cfr803, in compliance with the medical device reporting requirement and should not be considered to be an admission that an avanos medical, inc.Product is defective or caused serious injury.
|
| |
|
Event or Problem Description
|
|
It was reported there was a "premature rupture of the pexie wires occurred the day after gpr [percutaneous radiologic gastrostomy] placement, performed on (b)(6) 2025 (with loss of all 3 studs).The clinical consequence was a wall abscess requiring nosocomial antibiotic therapy.The probe had to be removed pending healing of the infection before reinsertion.".
|
| |
|
Additional Manufacturer Narrative
|
|
The device history record for the reported lot number, 30349612, in this complaint was reviewed and the material was produced according to the manufacturing procedures and met the quality requirements.Root cause could not be determined.All information reasonably known as of 26-nov-2025 has been included in this health authority report.Should additional information be obtained, a follow-up health authority report will be provided.The information provided by avanos medical, inc.Represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to avanos medical, inc.Avanos medical, inc.Has no independent knowledge of the event reported but is relaying the information that was provided by the user facility where the incident occurred.This product incident is documented in the avanos medical, inc.Complaint database and identified as complaint (b)(4).This information is submitted pursuant to 21cfr803, in compliance with the medical device reporting requirement and should not be considered to be an admission that an avanos medical, inc.Product is defective or caused serious injury.
|
| |
|
Search Alerts/Recalls
|
|
|