W. L. GORE & ASSOCIATES, INC. GORE® EXCLUDER® ILIAC BRANCH ENDOPROSTHESIS; SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT
|
Back to Search Results |
|
| Catalog Number |
HGB161007A |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Code |
Obstruction/Occlusion (2422)
|
| Date of Event |
10/28/2025
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
A review of the manufacturing records for the device verified that the lot met all pre-release specifications.W.L.Gore & associates, inc.(gore) is submitting this report to comply with 21 c.F.R.Part 803, the medical device reporting regulation.This report is based upon information obtained by gore, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Blank fields present on this report include required fields and fields determined to be not applicable.Blank required fields indicate that the information was not provided, was deemed unavailable or was not applicable.This report does not constitute an admission or a conclusion by fda, gore, or its associates that the device, gore or its associates caused or contributed to the event described in the report.In particular, this report does not constitute a legal admission by anyone that the product described in this report has any defects or has malfunctioned, as defined from a legal standpoint.These words are included in the report and are fixed items for selection created by the fda, to categorize the type of event solely for the purpose of reporting pursuant to part 803.This statement should be included with any information or report disclosed to the public under the freedom of information act.
|
| |
|
Event or Problem Description
|
|
The following information was reported to gore: on (b)(6) 2025, the patient underwent endovascular treatment for an abdominal aortic aneurysm using the gore® excluder® conformable aaa endoprosthesis, gore® excluder® aaa endoprosthesis, and the gore® excluder® iliac branch endoprosthesis (ibe).When deploying the ibe on the patient¿s left side, the internal iliac component (iic) remained patent; however, blood flow to the distal portion of the iic could not be confirmed.During insertion of a selective vascular catheter (kmp catheter) for iic placement, a possible dissection of the distal iic was considered.Blood flow to the distal iic remained unclear, and it was managed with observation.During deployment of the trunk-ipsilateral leg endoprosthesis, it was reported that the contralateral gate did not fully expand due to the patient¿s vascular anatomy.After deploying the ipsilateral leg first, the gate opened, and cannulation was successful.In addition, because the trunk-ipsilateral leg endoprosthesis had migrated approximately 7 mm distally, an aortic extender endoprosthesis was additionally placed proximally.Due to the patient¿s anatomic constraint, the origin of the iliac branch component was narrowed, and a bare-metal stent was placed.The procedure was then completed.
|
| |
|
Search Alerts/Recalls
|
|
|